Background: Noise-induced hearing loss (NIHL) is a serious concern for orthopedic surgeons. The National Institute for Occupational Safety and Health (NIOSH) sets the safe exposure limit at 85 dB for 8 hours, yet operating rooms often surpass this limit. This study investigated if using an automated broaching system exposes orthopedic surgeons to dangerous decibel (dB) levels. Materials and Methods: A prospective study analyzed 138 intraoperative sound recordings from 92 total hip arthroplasty (THA) surgeries and 46 baseline measurements at an academic-affiliated private practice, using the NIOSH Sound Level Meter (SLM) application and a microphone. The surgeries were categorized into manual and automated broaching. Key metrics measured included maximal dB level (MDL), peak sound pressure (LC peak ), average continuous sound (LA eq ), and average weighted sound in an 8-hour period (TWA), along with dose representations, to identify hazardous noise levels. Results: Of the 92 THA sound recordings, 50 used manual broaching and 42 employed automated broaching. Automated broaching exhibited higher noise levels, with an average MDL of 109.92 dBA, a LA eq of 86.09 dBA, a TWA of 76.48 dBA, and a projected noise dose of 137.74%. In contrast, manual broaching exhibited an average MDL of 105.87 dBA, a LA eq of 83.06 dBA, a TWA of 72.82 dBA, and a projected noise dose of 82.02%. Conclusion: This study highlights the auditory risks from automated broach and manual THA surgeries that orthopedic surgeons experience. Manufacturers should focus on reducing instrument noise when designing surgical tools and orthopedic surgeons and operating room staff should take measures to protect themselves from NIHL during surgery. [ Orthopedics . 202x;4x(x):xx–xx.]
Background: Noise-induced hearing loss (NIHL) is a serious concern for orthopedic surgeons. The National Institute for Occupational Safety and Health (NIOSH) sets the safe exposure limit at 85 dB for 8 hours, yet operating rooms often surpass this limit. This study investigated if using an automated broaching system exposes orthopedic surgeons to dangerous decibel (dB) levels. Materials and Methods: A prospective study analyzed 138 intraoperative sound recordings from 92 total hip arthroplasty (THA) surgeries and 46 baseline measurements at an academic-affiliated private practice, using the NIOSH Sound Level Meter (SLM) application and a microphone. The surgeries were categorized into manual and automated broaching. Key metrics measured included maximal dB level (MDL), peak sound pressure (LC peak ), average continuous sound (LA eq ), and average weighted sound in an 8-hour period (TWA), along with dose representations, to identify hazardous noise levels. Results: Of the 92 THA sound recordings, 50 used manual broaching and 42 employed automated broaching. Automated broaching exhibited higher noise levels, with an average MDL of 109.92 dBA, a LA eq of 86.09 dBA, a TWA of 76.48 dBA, and a projected noise dose of 137.74%. In contrast, manual broaching exhibited an average MDL of 105.87 dBA, a LA eq of 83.06 dBA, a TWA of 72.82 dBA, and a projected noise dose of 82.02%. Conclusion: This study highlights the auditory risks from automated broach and manual THA surgeries that orthopedic surgeons experience. Manufacturers should focus on reducing instrument noise when designing surgical tools and orthopedic surgeons and operating room staff should take measures to protect themselves from NIHL during surgery. [ Orthopedics . 202x;4x(x):xx–xx.]
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.