2024
DOI: 10.1177/03915603231220109
|View full text |Cite
|
Sign up to set email alerts
|

Robot-assisted partial nephrectomy using the novel Hugo™ RAS system: Feasibility, setting and perioperative outcomes of the first off-clamp series

F Prata,
A Ragusa,
A Civitella
et al.

Abstract: Introduction: Hugo Robot-Assisted Surgery (RAS) System has been conceived with enhanced modularity but its role for nephron-sparing surgery setting still remains poorly explored. We aimed to describe our experience in robot-assisted partial nephrectomy (RAPN) with a three-arms setting for the first off-clamp series using the new Hugo RAS System. Methods: Patients were placed on an extended flank position at the margin of the surgical bed with a slightly flexion (45°). The first 11 mm robotic trocar (camera por… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 34 publications
0
6
0
Order By: Relevance
“…The remaining 59 studies included in our systematic review were noncomparative surgical series or case reports [30] , [31] , [32] , [33] , [34] , [35] , [36] , [37] , [38] , [39] , [40] , [41] , [42] , [43] , [44] , [45] , [46] , [47] , [48] , [49] , [50] , [51] , [52] , [53] , [54] , [55] , [56] , [57] , [58] , [59] , [60] , [61] , [62] , [63] , [64] , [65] , [66] , [67] , [68] , [69] , [70] , [71] , [72] , [73] , [74] , [75] , [76] , [77] , [78] , [79] , [80] , [81] , [82] , [83] , [84] , [85] , [86] , [87] , [88] .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The remaining 59 studies included in our systematic review were noncomparative surgical series or case reports [30] , [31] , [32] , [33] , [34] , [35] , [36] , [37] , [38] , [39] , [40] , [41] , [42] , [43] , [44] , [45] , [46] , [47] , [48] , [49] , [50] , [51] , [52] , [53] , [54] , [55] , [56] , [57] , [58] , [59] , [60] , [61] , [62] , [63] , [64] , [65] , [66] , [67] , [68] , [69] , [70] , [71] , [72] , [73] , [74] , [75] , [76] , [77] , [78] , [79] , [80] , [81] , [82] , [83] , [84] , [85] , [86] , [87] , [88] .…”
Section: Resultsmentioning
confidence: 99%
“…Twenty-six studies reporting clinical data for the Hugo RAS system were included in our review [20] , [21] , [22] , [23] , [24] , [25] , [30] , [31] , [32] , [33] , [34] , [35] , [36] , [37] , [38] , [39] , [40] , [41] , [42] , [43] , [44] , [45] , [46] , [47] , [48] , [49] . Table 2 summarises data from studies on urological surgical procedures performed using the Hugo RAS system according to the IDEAL framework.…”
Section: Resultsmentioning
confidence: 99%
“…In other urological robotic interventions as well, initial reports on the utilization of Hugo TM RAS system seem to validate the feasibility and safety of the procedures conducted [27][28][29][30].…”
Section: Discussionmentioning
confidence: 96%
“…While the laparoscopic approach is still preferred mainly due to lower costs compared to robotic surgery, the advent of new platforms is changing the landscape of the medical market. The Hugo™ RAS System by Medtronic was recently introduced as a novel robotic tool characterized by four independent arm-cart dockings and augmented modularity, showing promising initial results [13,19,22]. The system consists of a console with two arm controllers operated with a grip similar to a pistol; a footswitch controlling the camera, energy source, and reserve arm; and four separate arm carts with six joints each for an increased range of motion.…”
Section: Discussionmentioning
confidence: 99%
“…Trocar configuration in RAPN using the Hugo™ RAS System was recently described in a three-arms setting [14,22], which involved an initial 11 mm robotic camera trocar along the pararectal line, positioned approximately 14 ± 2 cm away from the umbilicus. Two additional 8 mm operative robotic ports were placed under direct vision caudal to the endoscope trocar, which ensured appropriate distances from the optical port.…”
Section: Trocar Configuration and Surgical Proceduresmentioning
confidence: 99%