2017
DOI: 10.14797/mdcj-13-1-34
|View full text |Cite
|
Sign up to set email alerts
|

Robotic-Assisted Inferior Vena Cava Filter Retrieval

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2017
2017
2025
2025

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…Additionally, robotics can also find its use in the retrieval of inferior vena cava (IVC) filters. 38 IVC filters can be used as alternative therapy for VTE in those individuals who fails anticoagulation therapy. However, filters can only be used for short term, as their extended use may be associated with several complications, thus calling for timely retrieval.…”
Section: Clinical Applications Of Ai-assisted Robotics In Thrombosismentioning
confidence: 99%
“…Additionally, robotics can also find its use in the retrieval of inferior vena cava (IVC) filters. 38 IVC filters can be used as alternative therapy for VTE in those individuals who fails anticoagulation therapy. However, filters can only be used for short term, as their extended use may be associated with several complications, thus calling for timely retrieval.…”
Section: Clinical Applications Of Ai-assisted Robotics In Thrombosismentioning
confidence: 99%
“…13 This would have been hard to achieve with a conventional catheter owing to limited stability and trackability. Other reports describe the use of the system in vena cava filter retrieval, 14 stenting of a tight pulmonary artery stenosis, 15 retrieval of a foreign body within the pulmonary arterial tree, 16 and coil embolisation of an ascending aortic pseudoaneurysm. 17 Although these clinical reports certainly illustrate the feasibility and potential advantages of robotic navigation platforms across a range of clinical scenarios, clinical trial data is lacking and this may be in part because of the recognition by clinicians that the routine use of the robotic platform in straightforward index cases may not be cost-effective.…”
Section: The Current State and The Future Directionmentioning
confidence: 99%
“…Inferior vena cava (IVC) filter placement is indicated for any contraindication to anticoagulation in the presence of deep vein thrombosis (DVT). Placement is recommended to be less than 3 to 4 months, and the mainstay of standard removal has been via the endovascular approach, mainly snare techniques (1,2). However, complications can occur after IVC filter placement, including malposition, caval penetration, and filter fracture.…”
Section: Introductionmentioning
confidence: 99%