2022
DOI: 10.1089/ten.tec.2022.0053
|View full text |Cite
|
Sign up to set email alerts
|

Robust, Automated Analysis of Electrophysiology in Induced Pluripotent Stem Cell-Derived Micro-Heart Muscle for Drug Toxicity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
2

Relationship

3
3

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 37 publications
0
9
0
Order By: Relevance
“…Videos were imaged at 200–450 fps. The MATLAB Bio-Formats package was used along with custom MATLAB software 41 to calculate waveform parameters. To calculate conduction velocity, a modified version of the open-source MATLAB software Rhythm 1.0 developed by Laugher et al was used.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Videos were imaged at 200–450 fps. The MATLAB Bio-Formats package was used along with custom MATLAB software 41 to calculate waveform parameters. To calculate conduction velocity, a modified version of the open-source MATLAB software Rhythm 1.0 developed by Laugher et al was used.…”
Section: Methodsmentioning
confidence: 99%
“…In our prior study, we observed no substantial difference in beat rate correction by Fridericia's formula vs other formulas used for iPS-CM and clinical ECG. 41 …”
Section: Methodsmentioning
confidence: 99%
“…Calcium transients were captured by imaging endogenously expressed GcaMP6f in the GFP channel (4). Videos was analyzed via custom build code; intensity profile and kinetics parameters were automatically extracted (84). For calcium transient dynamics, initial baseline to 80% of the intensity was measured as UPD80, plateau region of more than 80% intensity was measured, decay times from end of the plateau to 50 and 75% decay of intensity was characterized.…”
Section: Action Potential and Calcium Measurementsmentioning
confidence: 99%
“…Along with the increasing efforts to fully differentiate CMs from pluripotent stem cells and, hence, derive functional engineered cardiac tissues, research is also focusing on designing and developing devices that can monitor in real-time and thus allow to progressively follow and reconstruct the whole tissue dynamics, also in response to exogenous stimuli. Technical challenges exist in the full thickness analysis but several researchers have developed advanced stimulating/sensing methods and equipment, e.g., microscopy visualization, contractility measurements, mechanical manipulation, and related high-throughput data collection that can easily combine with the engineered tissue models and, therefore, create automated, integrated platforms for robust readout ( Ramade et al, 2014 ; Pointon et al, 2017 ; Sasaki et al, 2018 ; Gracioso Martins et al, 2021 ; Ohya et al, 2021 ; Sasaki et al, 2021 ; Oguntuyo et al, 2022 ). So far, a relatively short time of a few hours or days has been dedicated to observing drug-induced alterations.…”
Section: Unmet Needs and Issues To Be Addressed For Clinical Translationmentioning
confidence: 99%