2022
DOI: 10.1109/tpwrd.2021.3110326
|View full text |Cite
|
Sign up to set email alerts
|

Robust Decoupled Outer-Control Design for Single VSC and HVDC Grid With Controller Weak AC System Interconnection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 20 publications
0
6
0
Order By: Relevance
“…The required input information of the proposed algorithm includes the data set of the studied system U-I characteristics, C eq , and the external system equivalent model, SEE. A set of interpolated equations, F eq , is obtained to approximate the studied system U-I characteristic as expressed in (4), ( 5) and (6). Then, the system of equations modeling the complete system can be defined with F eq and a subset of external system equivalent model, SEE k , corresponding to a combination k. The operation point, OP , can be obtained by solving SEO k for each combination k ∈ [1, K] using the solution function defined previously.…”
Section: B Methodology To Identify Operation Pointsmentioning
confidence: 99%
“…The required input information of the proposed algorithm includes the data set of the studied system U-I characteristics, C eq , and the external system equivalent model, SEE. A set of interpolated equations, F eq , is obtained to approximate the studied system U-I characteristic as expressed in (4), ( 5) and (6). Then, the system of equations modeling the complete system can be defined with F eq and a subset of external system equivalent model, SEE k , corresponding to a combination k. The operation point, OP , can be obtained by solving SEO k for each combination k ∈ [1, K] using the solution function defined previously.…”
Section: B Methodology To Identify Operation Pointsmentioning
confidence: 99%
“…However, these insights may not directly apply to VSCs connected to weak grids within MTDC grids, especially when droop voltage control is implemented, due to the potential of increased interactions among VSCs. The small-signal stability of an MTDC grid interfaced with weak ac systems was investigated in [34]- [36]. In [35], a methodology based on participation factor analysis was proposed to distinguish local and inter-area oscillation modes.…”
Section: Introductionmentioning
confidence: 99%
“…The shortcoming of this method is its dependency on the system states, which increases redundancy degree as the system becomes larger, and this would be problematic in the controller design. In [26], impedance-based modelling and H ∞ techniques are employed to identify the coupling in the power loops that depends on the network inductance and system operating point. The robust controller tuning with pole-placement and minimization of H∞ norm is fulfilled for HVDC grids, which form a restricted feedback system.…”
Section: Introductionmentioning
confidence: 99%