“…x T (𝐷 + 𝐶)𝑥 ≥ 𝜆 1 (𝐷 + 𝐶)𝑥 𝑇 𝑥 (7) where x = {x1, ..., xn} is the state variable that should be exchanged between the neighboring DG units, ci is the interest pinning, c = diag {c1, ..., cn}, λ2 is the second smallest eigenvalue of D which is also returned to algebraic connection D and λ1 is the smallest eigenvalue of (D + C).…”
Section: A Graph Theorymentioning
confidence: 99%
See 1 more Smart Citation
“…x T (𝐷 + 𝐶)𝑥 ≥ 𝜆 1 (𝐷 + 𝐶)𝑥 𝑇 𝑥 (7) where x = {x1, ..., xn} is the state variable that should be exchanged between the neighboring DG units, ci is the interest pinning, c = diag {c1, ..., cn}, λ2 is the second smallest eigenvalue of D which is also returned to algebraic connection D and λ1 is the smallest eigenvalue of (D + C).…”
Section: A Graph Theorymentioning
confidence: 99%
“…For each of these modes, various control structures have been presented. In [5]- [7], PQ control for the network-connected mode was proposed. Given that, in this case, the voltage and frequency are provided by the main network, only adjusting the grid's overlapping power and applying proper power sharing are required.…”
Section: Introductionmentioning
confidence: 99%
“…However, these techniques are plagued by unsatisfactory steady‐state performances with low signal‐to‐noise ratios. To overcome the issues in convergence rate of weight signals and less mean square deviation, the mixed LMS–LMF technique has been reported in Srinivas et al 14 A robust normalized mixed‐norm (RNMN) adaptive control to overcome convergence rate and steady‐state stability problems is documented in Chishti 15 . A least mean mixed‐norm (LMMN) control with lesser mean square error (MSE) and accelerated convergence for the extrication of fundamental components is proposed in Chisti et al 16 An adaptive reweighted zero attracting least mean square (RZA‐LMS) control with self‐adjusting step size capability to minimize MSE and approached quickly is reported in Nazir et al 17 …”
Section: Introductionmentioning
confidence: 99%
“…grid‐connected mode), where the RESs are utilized to extract the maximum of the available power, supply it to the connected loads and the surplus power is transferred to the utility grid [4]. The main intention of grid‐connected RESs‐based generation systems is to transfer a better‐quality current to the utility grid despite the presence of local loads at the point of common coupling (PCC) [5]. However, in the grid‐connected WTs‐/PV arrays‐based DGSs, the operating conditions other than the rated wind speed/solar insolation result in low energy conversion efficiency.…”
Section: Introductionmentioning
confidence: 99%