2018
DOI: 10.1038/s41598-018-34121-3
|View full text |Cite
|
Sign up to set email alerts
|

Robust sensing suite for measuring temporal dynamics of surface temperature in sewers

Abstract: Sewerage systems are paramount underground infrastructure assets for any nation. In most cities, they are old and have been exposed to significant microbial induced corrosion. It is a serious global problem as they pose threats to public health and economic repercussions to water utilities. For managing sewer assets efficaciously, it is vital to predict the rate of corrosion. Predictive models of sewer corrosion incorporate concrete surface temperature measurements as an observation. However, currently, it has… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
25
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
3
2

Relationship

4
5

Authors

Journals

citations
Cited by 40 publications
(25 citation statements)
references
References 19 publications
0
25
0
Order By: Relevance
“…Besides direct measurements, predictive models have been developed for estimating the corrosion throughout the sewer network. Quality of such model prediction rely on the data supplies by the sensors [21,22,23,24].…”
Section: Conventional Ndt Sensing Modalitiesmentioning
confidence: 99%
“…Besides direct measurements, predictive models have been developed for estimating the corrosion throughout the sewer network. Quality of such model prediction rely on the data supplies by the sensors [21,22,23,24].…”
Section: Conventional Ndt Sensing Modalitiesmentioning
confidence: 99%
“…Those models primarily incorporate air temperature, relative humidity, and hydrogen sulphide concentration of sewer air as data inputs to the model [14]. Also, the model takes surface temperature sensor measurements [15], [16] and surface moisture sensor measurements [17]- [19] as additional inputs to reduce prediction uncertainty. This predictive analytics based corrosion estimation needs longterm sensor inputs.…”
Section: Introductionmentioning
confidence: 99%
“…The sensor was deployed on 3 rd November 2016. The readers are suggested to refer [15] for more details on sensor deployment. This paper proposes a temporal forecasting driven approach for anomaly detection in sewer air temperature sensor system.…”
Section: Introductionmentioning
confidence: 99%
“…The predictive performance of the model can be improved in areas where there is low confidence in estimating corrosion by supplying concrete surface temperature and moisture conditions as data inputs to the model [8]- [13]. Recently, a robust sensing suite for monitoring the temporal variations of concrete surface temperature conditions was developed [14]. The data inputs from this sensor are crucial for accurate sewer pipe corrosion prediction.…”
Section: Introductionmentioning
confidence: 99%