2015
DOI: 10.1016/j.measurement.2014.12.005
|View full text |Cite
|
Sign up to set email alerts
|

Rogowski coil current transducer compensation method for harmonic active power error

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 27 publications
0
4
0
Order By: Relevance
“…The aim is to overcome the limitations of the state-of-the-art where fault diagnosis is usually implemented for a single type of components of an UPS system, e.g., only power transformers in [7,8, or only battery modules for energy storage in [14][15][16][42][43][44][45][46][47]. In the state-of the-art often only some types of faults are addressed, e.g., [32][33][34][35][36][37][38][39][40][41] address only electrical and In Figure 10 moving from the original cell to the last curve an increaseˆ1.6 is detected in terms of R s andˆ1.5 in terms of f c . Figure 11 shows for all the cells in a string the distribution of operating voltage after the 4 months of accelerated aging tests.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The aim is to overcome the limitations of the state-of-the-art where fault diagnosis is usually implemented for a single type of components of an UPS system, e.g., only power transformers in [7,8, or only battery modules for energy storage in [14][15][16][42][43][44][45][46][47]. In the state-of the-art often only some types of faults are addressed, e.g., [32][33][34][35][36][37][38][39][40][41] address only electrical and In Figure 10 moving from the original cell to the last curve an increaseˆ1.6 is detected in terms of R s andˆ1.5 in terms of f c . Figure 11 shows for all the cells in a string the distribution of operating voltage after the 4 months of accelerated aging tests.…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, known works often address only some types of faults: e.g., [32][33][34][35][36][37][38][39][40][41] address only electrical and thermal faults, whereas [23,28,31] address only mechanical faults through visual inspection or acoustic analysis. For diagnosis of power transformers just the measurement of some electrical parameters is foreseen in state-of-the-art such as in [34,35,39], which measure the primary or secondary currents or their ratio, or in [36], which measures the insulation dielectric losses, or in [40,41], which measure no-load power losses, or in [33], which measures the stray reactance variations.…”
Section: Critical Analysis Of the State-of-the-art For Ups Predictivementioning
confidence: 99%
See 1 more Smart Citation
“…Rogowski coils are lightweight and if made flexible they can be easily mounted on existing conductors, but they measure only AC or pulse currents since they are based on the induction law. [7]. The B-Dot sensors work on the same principle, using flat coils made of multilayer PCB [8].…”
Section: Introductionmentioning
confidence: 99%