Role of an Anterior Flange on Cortical Strains Through the Distal Humerus After Total Elbow Arthroplasty With a Latitude Implant

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
9
0
2

Year Published

2011
2011
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(14 citation statements)
references
References 13 publications
3
9
0
2
Order By: Relevance
“…sind luxationsgesichert und haben eine zusätzliche ventrale Abstützung für den Fall der unzureichenden Abstützung an den Kondylen (Quenneville et al 2008), obwohl der Wert der ventralen Abstützung biomechanisch nicht geklärt ist. 5.50a, b), die sich in einer übermäßigen Achslaxität bis hin zu manifesten Achsschäden selbst bei stärker dimensionierten Buchsen der Coonrad-Morrey-Prothese manifestierten .…”
Section: Ergebnisseunclassified
See 1 more Smart Citation
“…sind luxationsgesichert und haben eine zusätzliche ventrale Abstützung für den Fall der unzureichenden Abstützung an den Kondylen (Quenneville et al 2008), obwohl der Wert der ventralen Abstützung biomechanisch nicht geklärt ist. 5.50a, b), die sich in einer übermäßigen Achslaxität bis hin zu manifesten Achsschäden selbst bei stärker dimensionierten Buchsen der Coonrad-Morrey-Prothese manifestierten .…”
Section: Ergebnisseunclassified
“…Damit minimieren sich die Kräfte auf das Implantatlager, was sich in reduzierten Lockerungsraten bei mittelfristiger Beobachtung auf 6-10 % dokumentierte (Quenneville et al 2008;Scheier 1975). Damit minimieren sich die Kräfte auf das Implantatlager, was sich in reduzierten Lockerungsraten bei mittelfristiger Beobachtung auf 6-10 % dokumentierte (Quenneville et al 2008;Scheier 1975).…”
Section: Ergebnisseunclassified
“…The humeral component is porous-coated distally and presents an anterior flange, which increases the rotational stability of the implant and neutralizes the extension forces transmitted to the implant interface. The benefit of an anterior flange has been investigated for other implants as well [2]. The ulnar component has a plasma-spray metallic coating in its proximal third.…”
Section: Materials and Designsmentioning
confidence: 99%
“…The triangular prosthesis within a triangular distal humeral canal is thought to provide the theoretical advantage of rotational stability (Fig. 17 Testing of the load transfer in the distal humerus after the insertion of a humeral component with an anterior flange with no graft, with cancellous graft, and with bone cement demonstrated no significant differences in cortical strains with the 3 different flange grafts. (b) Custom made triflange outrigger ulnar components have been introduced because it has been recognized that torsional forces are a significant mode of failure of the ulnar component in patients with absent humeral epicondyles and additional risk factors for accelerated bushing wear.…”
Section: Historical Perspectivementioning
confidence: 99%
“…3). 17 A possible explanation is that, at time 0 after a revision or primary TEA and during the early postoperative period, the rotational control of the humeral component is problematic because time is required for formation of bone around the flange and the cancellous allograft has not been incorporated to the native humerus. 16 (c) Some humeral components have also an extramedullary flange on their distal portion to resist posterior displacement and torsional stresses by inserting FIGURE 2.…”
Section: Historical Perspectivementioning
confidence: 99%