2006
DOI: 10.1016/j.echo.2006.04.016
|View full text |Cite
|
Sign up to set email alerts
|

Role of Biplane and Biplane Echocardiographically Guided 3-Dimensional Echocardiography During Dobutamine Stress Echocardiography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
34
0
2

Year Published

2007
2007
2015
2015

Publication Types

Select...
5
3
1

Relationship

1
8

Authors

Journals

citations
Cited by 43 publications
(38 citation statements)
references
References 13 publications
2
34
0
2
Order By: Relevance
“…However, an important advantage of the RT3DE approach, in addition to faster acquisition, was its ability to extract offline multiple short-and long-axis views of the ventricle that can help in determining the extent of wall motion abnormality and in ruling out artifacts frequently noted in standard imaging planes caused by limited endocardial visualization. Another study 30 demonstrated high levels of agreement with 2DE-based wall motion scores.…”
Section: Rt3de Assessment Of Regional Wall Motionmentioning
confidence: 93%
“…However, an important advantage of the RT3DE approach, in addition to faster acquisition, was its ability to extract offline multiple short-and long-axis views of the ventricle that can help in determining the extent of wall motion abnormality and in ruling out artifacts frequently noted in standard imaging planes caused by limited endocardial visualization. Another study 30 demonstrated high levels of agreement with 2DE-based wall motion scores.…”
Section: Rt3de Assessment Of Regional Wall Motionmentioning
confidence: 93%
“…4.2). Typically, the biplanar mode from the parasternal echo window allows the simultaneous acquisition of a long axis and of an adapted short axis, and from the apical echo window a simultaneous apical 4-chamber and 2-chamber view [3] [4]. Finally -using the rotation of one of the image planes -in a third heartbeat the apical long axis can be acquired (.…”
Section: Methodsmentioning
confidence: 99%
“…Importantly, a shorter scanning time did not reduce test accuracy. Several studies on the use of full volume 3D echocardiography [4] …”
Section: 2mentioning
confidence: 99%
“…The feasibility of 3-D dobutamine stress echocardiography has been previously demonstrated. 170,171 3-D imaging during stress echocardiography offers the promise of shorter imaging times and truly tomographic views. 172,173 With further technical improvements, 3-D is expected to further improve the accuracy and efficiency of stress echocardiography.…”
Section: -Dimensional Stress Echocardiographymentioning
confidence: 99%