2015
DOI: 10.1016/j.ejrnm.2015.01.001
|View full text |Cite
|
Sign up to set email alerts
|

Role of dynamic contrast enhanced MR perfusion in differentiation between benign and malignant tumors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…El Backry et al 17 studied the role of DCE‐MRI in differentiating benign from malignant head and neck neoplasms with a sample size of 55 patients wherein they found 82% of the benign tumors showing gradual progressing and plateau curves, whereas 93% of malignant tumors displayed plateau and fast curves. Among the evaluated perfusion parameters, wash‐in rate with a cutoff value of 15.4/s (sensitivity: 87.9%, specificity: 90.0%) was adjudged as the best parameter for differentiating benign from malignant tumors.…”
Section: Discussionmentioning
confidence: 99%
“…El Backry et al 17 studied the role of DCE‐MRI in differentiating benign from malignant head and neck neoplasms with a sample size of 55 patients wherein they found 82% of the benign tumors showing gradual progressing and plateau curves, whereas 93% of malignant tumors displayed plateau and fast curves. Among the evaluated perfusion parameters, wash‐in rate with a cutoff value of 15.4/s (sensitivity: 87.9%, specificity: 90.0%) was adjudged as the best parameter for differentiating benign from malignant tumors.…”
Section: Discussionmentioning
confidence: 99%
“…A total of 55 patients with head and neck masses were evaluated by Backry et al 10 Four TIC patterns were described: Type A (gradual enhancement), type B (rapid enhancement and low washout), type C (rapid enhancement and fast washout), and type D (flat). It was found that most of the benign tumors showed type A curve while malignant tumors showed type C curve while curve B and D were statistically insignificant.…”
Section: Dce-mrimentioning
confidence: 99%
“…10,12 Only one study used quantitative dynamic contrast-enhanced MRI (DCE-MRI) parameters with STA but in a small percentage of included cases (3/55, 5.5%). 13 No reports focused on only STA.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, to date only 11 cases have been reported regarding the apparent diffusion coefficient (ADC) values of STA 10,12 . Only one study used quantitative dynamic contrast‐enhanced MRI (DCE‐MRI) parameters with STA but in a small percentage of included cases (3/55, 5.5%) 13 . No reports focused on only STA.…”
Section: Introductionmentioning
confidence: 99%