“…Recent centrifuge (Xu et al, 2020(Xu et al, , 2021b and numerical/analytical modelling studies (Fu et al, 2018;Elkayam and Klar, 2019;Boldini et al, 2021) have demonstrated the need to consider the full structural details for framed buildings, for the accurate analysis of their response to tunnelling, highlighting, in particular, the important role of shear stiffness. Importantly, those studies primarily focused on buildings founded on the ground surface, whereas the role of embedded foundations or basements on tunnel-frame interaction has received much less attention (Xu et al, 2021a). In congested urban environments, it is common for buildings to have basements, which then alter their response to nearby tunnel construction when compared to equivalent buildings resting directly on the ground surface.…”