Roll Angular Rate Measurement for High Spinning Projectiles Based on Redundant Gyroscope System

Abstract: Precision-guided projectiles, which can significantly improve the accuracy and efficiency of fire strikes, are on the rise in current military engagements. The accurate measurement of roll angular rate is critical to guide a gun-launched projectile. However, Micro-Electro-Mechanical System (MEMS) gyroscope with low cost and large range cannot meet the requirement of high precision roll angular rate measurement due to the limitation by the current technology level. Aiming at the problem, the optimization-based … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 38 publications
0
4
0
Order By: Relevance
“…According to the model, a Kalman filter is used for data fusion. The system noise matrix and measurement noise matrix in the Kalman filter are set according to the noise parameters obtained by Allan variance [20][21][22][23], as shown in Figure 5 below: The output error model of the MEMS gyroscope is shown as follows [24][25][26][27]:…”
Section: Data Fusion Of Redundant Mems-imumentioning
confidence: 99%
See 1 more Smart Citation
“…According to the model, a Kalman filter is used for data fusion. The system noise matrix and measurement noise matrix in the Kalman filter are set according to the noise parameters obtained by Allan variance [20][21][22][23], as shown in Figure 5 below: The output error model of the MEMS gyroscope is shown as follows [24][25][26][27]:…”
Section: Data Fusion Of Redundant Mems-imumentioning
confidence: 99%
“…Figure 5. Redundant MEMS-IMU data fusion flowchart.The output error model of the MEMS gyroscope is shown as follows[24][25][26][27]:…”
mentioning
confidence: 99%
“…From the above equation, the condition that CRM can completely eliminate the influence of bias error is shown in Equation (7).…”
Section:  mentioning
confidence: 99%
“…Among them, the redundant sensor-based random error measurement scheme and the RSSINS-based sensor constant error compensation scheme have significantly improved the navigation accuracy of guided artillery shells [5][6][7][8]. At the same time, considering the high impact and high rotary velocity of the shell, MEMS sensors have been widely used.…”
Section: Introductionmentioning
confidence: 99%