2015
DOI: 10.1007/s10853-015-9555-2
|View full text |Cite
|
Sign up to set email alerts
|

Room-temperature and fast response hydrogen sensor based on annealed nanoporous palladium film

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
6
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(7 citation statements)
references
References 17 publications
1
6
0
Order By: Relevance
“…Grain size growth might be one of the factors causing change of H absorption. In addition, the internal stress in alloy film was released after annealing treatment, which might be another factor for the fast response time [ 8 , 20 ]. The output signal, the response and recovery time of the annealed hydrogen sensor all decrease after annealing treatment.…”
Section: Resultsmentioning
confidence: 99%
“…Grain size growth might be one of the factors causing change of H absorption. In addition, the internal stress in alloy film was released after annealing treatment, which might be another factor for the fast response time [ 8 , 20 ]. The output signal, the response and recovery time of the annealed hydrogen sensor all decrease after annealing treatment.…”
Section: Resultsmentioning
confidence: 99%
“…Compared with the state-of-the art Pd and PdAg hydrogen sensor, although the output response is relatively smaller, the repeatability of the sensor is similar [ 13 , 16 ]. Particularly, the size of this MEMS based hydrogen sensor is much smaller and easy for integration.…”
Section: Resultsmentioning
confidence: 99%
“…Grain size growth might be one of the factors causing change of H absorption. In addition, the internal stress in alloy film was released after annealing treatment, which might be another factor for the fast response time [17,18]. The output signal, the response and recovery time of the annealed hydrogen sensor all decrease after annealing treatment.…”
Section: Preprintsmentioning
confidence: 99%
“…In the past decades, palladium (Pd) and palladium alloy were widely used as the sensitive materials for metallic resistor type hydrogen sensor due to its high solubility for hydrogen [2,3,17,18]. Although pure Pd could deliver a high output, fast response and superior selectivity of hydrogen, there are still some shortcomings, such as structural deformations and the consequent hysteretic resistance behavior [2,3].…”
Section: Introductionmentioning
confidence: 99%