2016
DOI: 10.1007/s11668-016-0074-5
|View full text |Cite
|
Sign up to set email alerts
|

Root Cause Failure Analysis and Mitigation of Corrosion in Seawater Injection Piping

Abstract: This paper illustrates the methodology for performing a root cause failure analysis of corrosion anomalies reported in the low pressure section of an FPSO seawater injection piping system. Specific practical actions are recommended for mitigating the identified root causes of failure. The primary root cause of failure is oxygen corrosion due to oxygen ingress at components upstream (u/s) and downstream (d/s) of the sulfate removal (SRM) pumps. Oxygen corrosion was worsened by underdeposit corrosion caused by u… Show more