2001
DOI: 10.1007/bf02482124
|View full text |Cite
|
Sign up to set email alerts
|

Round-robin test on chloride analysis in concrete — Part II: Analysis of water soluble chloride content

Abstract: In Part I of this paper, general trends in the realisation of this Round Robin Test on chloride analysis in concrete (carried out as part of the work developed by the Technical Committee TC 178-TMC), as well as the results corresponding to total chlorides were given. The present paper reports the results corresponding to the extraction of water soluble chlorides. Results concerning the determination of the penetration front of chlorides by colourirnetric techniques will be given in Part III. A total of 30 diff… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
3

Year Published

2002
2002
2019
2019

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 30 publications
(9 citation statements)
references
References 7 publications
0
6
0
3
Order By: Relevance
“…Se perforaron todos los cubos longitudinalmente en fases de 10 mm hasta una profundidad total de 50 mm. El polvo recogido en cada intervalo se guardó en bolsas herméticas de plástico hasta su análisis mediante titulación para determinar su contenido de cloruros (25,26).…”
Section: Test Proceduresunclassified
See 1 more Smart Citation
“…Se perforaron todos los cubos longitudinalmente en fases de 10 mm hasta una profundidad total de 50 mm. El polvo recogido en cada intervalo se guardó en bolsas herméticas de plástico hasta su análisis mediante titulación para determinar su contenido de cloruros (25,26).…”
Section: Test Proceduresunclassified
“…Each cube was drilled longitudinally in 10-mm stages to a total depth of 50 mm. The powder gathered at each interval was stored in airtight plastic bags until analysed for chloride content by titration (25,26).…”
Section: Calor De Hidrataciónmentioning
confidence: 99%
“…However, the best reliability was obtained when each laboratory extracted the chloride according to the method normally used. For the watersoluble chloride content, the round-robin test involved 20 laboratories and 37 measurements (Castellote and Andrade, 2001b). The values were compared to a target obtained from the pore expression technique.…”
Section: Advances In Cement Researchmentioning
confidence: 99%
“…En (18) se propone un método de extracción acuosa, y en (19) se desarrolla un método de lixiviación alcalina, basado en ideas dadas en (20). Ambos métodos (18) y (19), han sido validados en un ensayo interlaboratorios sobre análisis de cloruros (21).…”
Section: Introductionunclassified
“…In (18) a water extraction method has been proposed by AFREM, and in (19) an alkaline leaching method is developed by the authors, based on the ideas given in (20). Both methods, (18) and (19) have been validated in a Round Robin Test on chloride analysis (21).…”
Section: Introductionmentioning
confidence: 99%