2013
DOI: 10.1016/s0735-1097(13)60942-0
|View full text |Cite
|
Sign up to set email alerts
|

Routine Cine-CMR for Prosthesis Associated Mitral Regurgitation: A Multicenter Comparison to Echocardiography

Abstract: Background/Aim MR is an important complication after PMV. Transthoracic echocardiography is widely used to screen for native MR, but can be limited with PMV. Cine-CMR holds potential to non-invasively assess regurgitant severity based on MR-induced inter-voxel dephasing. This study evaluated routine cine-CMR for visual assessment of prosthetic mitral valve (PMV) associated mitral regurgitation (MR). Methods Routine cine-CMR was performed at 9 sites. A uniform protocol was used to grade MR based on jet size i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 22 publications
0
5
0
Order By: Relevance
“…67 Turbulent flow through a regurgitant orifice is easily visible with SSFP (visualization of signal voids due to spin dephasing in moving protons). 63,64 PHV anatomy can be imaged by acquisition of standard short-axis, two-, three-, and four-chamber long-axis views in combination with oblique long-axis cines orthogonal to the line of coaptation. 68 Leaflet motion restriction may be identified.…”
Section: Cardiovascular Magnetic Resonancementioning
confidence: 99%
See 1 more Smart Citation
“…67 Turbulent flow through a regurgitant orifice is easily visible with SSFP (visualization of signal voids due to spin dephasing in moving protons). 63,64 PHV anatomy can be imaged by acquisition of standard short-axis, two-, three-, and four-chamber long-axis views in combination with oblique long-axis cines orthogonal to the line of coaptation. 68 Leaflet motion restriction may be identified.…”
Section: Cardiovascular Magnetic Resonancementioning
confidence: 99%
“…15,21,27,29,134 Cinefluoroscopy, cardiac CT, or CMR can be used as complementary tools, if needed (see above). 39,42,64 On TTE, parasternal long-and short-axis views, and all apical views with multiple angulation and off-axis cuts are needed to scan the whole sewing ring, the mitral subvalvular apparatus, and the leaflet/occluder(s) motion. The stents of biological valve are often well seen in the apical four-chamber view.…”
Section: Imaging Assessmentmentioning
confidence: 99%
“…Cine-CMR is useful for the assessment of prosthetic mitral valve-associated MR, which manifests concordant quantitative and qualitative changes in size and density of inter-voxel dephasing. It provides an accurate non-invasive means of screening for TEE-evidenced severe MR (60) In one of the these studies, clinical benefit and LV remodeling had good correlation with CMR in post-procedural follow up. (61,62) This signifies an emerging role of CMR in clinical follow up of this subgroup of patients.…”
Section: Role Of 4d Cmrmentioning
confidence: 96%
“…Cine‐CMR is useful for the assessment of prosthetic mitral valve‐associated MR, which manifests concordant quantitative and qualitative changes in size and density of inter‐voxel dephasing. It provides an accurate noninvasive means of screening for TEE‐evidenced severe MR 70 . In one of these studies, clinical benefit and LV remodeling had good correlation with CMR in post‐procedural follow‐up.…”
Section: Comparison Of Cmr With Tte and Its Role In Prognostication Amentioning
confidence: 99%