Abstract:The analytical method was developed and validated for estimation of Brivaracetam in bulk and formulation by ReversePhase High performance liquid chromatography. The separation was carried out on Luna C8 (150 × 4.6mm, 5μm)column. The mobile phase consists of ACN: Water at flow rate 1 ml/min at 208nm. The column temperature wasadjusted at 30°C with injection volume 20μl. The retention time of Brivaracetam was 3.1 min. The linearity of thecalibration curve was linear over the concentration range 10-50 μg/ml. The … Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.