Abstract: The importance of graft-related endoleak, stent-graft disintegration and migration in the causation of aneurysm rupture was confirmed. Poor compliance with follow-up schedule was also identified as a common feature. However, the absence of complications in some patients, who attended regularly for follow-up, highlights the difficulty of predicting rupture after EVAR.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
151
1
2

Year Published

2004
2004
2022
2022

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 178 publications
(160 citation statements)
references
References 9 publications
2
151
1
2
Order By: Relevance
“…Thus, the association of type I endoleaks with an increased aneurysm rupture risk is a strong recommendation for treatment. 17,18 In such cases, an open aortic repair is generally performed in EVAR failure, despite a high mortality of up to 22%. 19 However, advanced age, suprarenal or supraceliac aortic clamping, and the technical challenge of endograft removal (stent incorporation into the aortic wall, presence of external stents or barbs, and periaortic inflammation) expose the patients to a high surgical risk, especially in the nonelective setting.…”
Section: Discussionmentioning
confidence: 99%
“…Thus, the association of type I endoleaks with an increased aneurysm rupture risk is a strong recommendation for treatment. 17,18 In such cases, an open aortic repair is generally performed in EVAR failure, despite a high mortality of up to 22%. 19 However, advanced age, suprarenal or supraceliac aortic clamping, and the technical challenge of endograft removal (stent incorporation into the aortic wall, presence of external stents or barbs, and periaortic inflammation) expose the patients to a high surgical risk, especially in the nonelective setting.…”
Section: Discussionmentioning
confidence: 99%
“…An endovascular device or Dacron bypass are fitted exactly to the aortic size, but if aortic size changes with time, particularly at the anastomosis sites, then late leaks and rupture can occur. 5,22 It is important to apply the findings of this study not only to the surveillance of small aneurysms, but also postoperative follow-up, particularly after endovascular repair. Patients need to appreciate that the durability of AAA repair could be threatened if they continue to smoke and the dilatation process continues.…”
Section: Brady Et Al Abdominal Aortic Aneurysm Expansionmentioning
confidence: 99%
“…6 Although the development of renal and mesenteric fenestration or branched stent graft technology to extend the landing zone more proximally may overcome type 1a endoleaks, these devices may not be ideal because of regulations, complexity, and manufacturing delays. 7 In addition, contemporary published literature does not provide sufficiently strong evidence to warrant a change in treatment guidelines for juxtarenal or short-neck aneurysm.…”
Section: 血管腔內主動脈瘤修復過程中使用近端修復 Palmaz支架置入來阻止血管滲漏的成效mentioning
confidence: 99%