2023
DOI: 10.3390/bios13100936
|View full text |Cite
|
Sign up to set email alerts
|

Ruthenium-Anchored Carbon Sphere-Customized Sensor for the Selective Amperometric Detection of Melatonin

Sivaguru Jayaraman,
Thenmozhi Rajarathinam,
Hyeon-Geun Jang
et al.

Abstract: Melatonin (MT), a pineal gland hormone, regulates the sleep/wake cycle and is a potential biomarker for neurodegenerative disorders, depression, hypertension, and several cancers, including prostate cancer and hepatocarcinoma. The amperometric detection of MT was achieved using a sensor customized with ruthenium-incorporated carbon spheres (Ru–CS), possessing C- and O-rich catalytically active Ru surfaces. The non-covalent interactions and ion–molecule adducts between Ru and CS favor the formation of heterojun… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 53 publications
0
3
0
Order By: Relevance
“…The following chemicals were received from Sigma–Aldrich (Seoul, Republic of Korea): ammonia aqueous solution (25–28%), aniline (99%), ammonium peroxydisulphate (APS) (Extrapure, 99%), hydrochloric acid (HCl, 37%), concentrated sulfuric acid (H 2 SO 4 , 98%), ethanol (99.5% purity), chloroform, MWCNTs (>95 wt%), potassium ferri and ferrocyanides [Fe(CN) 6 ] 3−/4− , potassium chloride (KCl), dopamine hydrochloride (DA), glucose, glutamate (Glu), norepinephrine (NE), serotonin (5–HT), ascorbic acid (AA), and uric acid (UA). Phosphate buffers (0.1 M) were prepared following a standard protocol reported elsewhere [ 23 ], and all solutions were prepared utilizing 18.2 MΩ cm water. Only aniline was distilled before use; all other chemicals were utilized exactly as they were supplied (analytical grade).…”
Section: Methodsmentioning
confidence: 99%
“…The following chemicals were received from Sigma–Aldrich (Seoul, Republic of Korea): ammonia aqueous solution (25–28%), aniline (99%), ammonium peroxydisulphate (APS) (Extrapure, 99%), hydrochloric acid (HCl, 37%), concentrated sulfuric acid (H 2 SO 4 , 98%), ethanol (99.5% purity), chloroform, MWCNTs (>95 wt%), potassium ferri and ferrocyanides [Fe(CN) 6 ] 3−/4− , potassium chloride (KCl), dopamine hydrochloride (DA), glucose, glutamate (Glu), norepinephrine (NE), serotonin (5–HT), ascorbic acid (AA), and uric acid (UA). Phosphate buffers (0.1 M) were prepared following a standard protocol reported elsewhere [ 23 ], and all solutions were prepared utilizing 18.2 MΩ cm water. Only aniline was distilled before use; all other chemicals were utilized exactly as they were supplied (analytical grade).…”
Section: Methodsmentioning
confidence: 99%
“…After ingestion through food, water, and air, the human body metabolizes and eliminates heavy metals in various ways, primarily through urine. The concentration of heavy metals in urine provides an indication of the body’s metal levels after metabolism ( 14 , 15 ). The International Association for Research on Cancer (IARC) has classified beryllium and beryllium-containing compounds as Group 1 carcinogens.…”
Section: Introductionmentioning
confidence: 99%
“…According to the response mechanism, electrochemical sensors can be classified into potentiometric, amperometric, and impedimetric sensors. Some recent advances in each of these classes can be found in references [25][26][27][28][29][30][31][32][33][34][35][36][37]. Although impedimetric sensors are often more sensitive than amperometric ones, these are commonly preferred due to the easier performance of the amperometry measure, as well as current data collection and interpretation [38].…”
Section: Introductionmentioning
confidence: 99%