Safety and efficacy of a non-polymeric paclitaxel-eluting microporous stent in real-world percutaneous coronary intervention

Abstract: At present, there is an increasing focus on stents that have a biodegradable polymer coating, rather than a permanent polymer coating. This is due to the fact that following the implantation of a drug-eluting stent (DES) with a permanent polymer coating, the continued existence of the coating may result in a foreign body reaction and delayed re-endothelialization. The aim of the present study was to evaluate the safety and efficacy of a non-polymeric paclitaxel-eluting microporous (YINYI™) stent in real-life p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 20 publications
0
1
0
Order By: Relevance
“…The VAO lesion was predilated routinely. Next, a stainless steel, balloon-expandable, paclitaxel-eluting stent with no polymer coating (Yinyi stent; Biomedical Materials R&D Center Co., Liaoning, China) 17 was mounted on the Nitrex guidewire or the filter’s guidewire in a monorail configuration and deployed to protrude 1 to 2 mm into the subclavian artery to guarantee complete coverage of the stenotic lesion. The stent was deployed at low pressure (6–8 atm) and postdilated at high pressure (10–12 atm) after withdrawing the balloon one half to one third outside the stent to ensure that the protruding strut provided sufficient coverage of the plaque.…”
Section: Methodsmentioning
confidence: 99%
“…The VAO lesion was predilated routinely. Next, a stainless steel, balloon-expandable, paclitaxel-eluting stent with no polymer coating (Yinyi stent; Biomedical Materials R&D Center Co., Liaoning, China) 17 was mounted on the Nitrex guidewire or the filter’s guidewire in a monorail configuration and deployed to protrude 1 to 2 mm into the subclavian artery to guarantee complete coverage of the stenotic lesion. The stent was deployed at low pressure (6–8 atm) and postdilated at high pressure (10–12 atm) after withdrawing the balloon one half to one third outside the stent to ensure that the protruding strut provided sufficient coverage of the plaque.…”
Section: Methodsmentioning
confidence: 99%