Safety and Efficacy of Low-Profile, Self-Expandable Stents for Treatment of Intracranial Aneurysms: Initial and Midterm Results - A Systematic Review and Meta-Analysis

Abstract: Low-profile stents seem to be associated with a higher incidence of thromboembolic events compared with preexisting stents. We conducted a systematic review of 11 eligible reports and a meta-analysis of 7 reports with respect to the clinical efficacy and safety of low-profile stents. There were 217 intracranial aneurysms reported; 22% were ruptured aneurysms. In all, 72% were treated using single stenting, 19% were treated using overlapping stenting, and 6% were treated using balloon angioplasty followed by st… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
20
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(21 citation statements)
references
References 18 publications
1
20
0
Order By: Relevance
“…However, the changes were only discreet and didn't require any therapy. In addition, there have been no in-stent stenoses, whereas in the literature a frequency of up to 10% is reported 28 .…”
Section: Discussionmentioning
confidence: 98%
“…However, the changes were only discreet and didn't require any therapy. In addition, there have been no in-stent stenoses, whereas in the literature a frequency of up to 10% is reported 28 .…”
Section: Discussionmentioning
confidence: 98%
“…The low-profile visualized intraluminal support (LVIS; MicroVention, Aliso Vajo, USA) device is a braided and self-expanding device, which has been used to treat broad-neck, complex cerebral aneurysms [1][2][3][4][5][6][7][8][9][10][11][12][13]. In a systematic review of the use of braided stents in early studies (2006)(2007)(2008)(2009)(2010)(2011)(2012)(2013)(2014)(2015)(2016)(2017) involving 35 studies comprising 1426 patients [14], the overall successful stent delivery and complete aneurysm occlusion rates were 97% and 88.3%, respectively.…”
Section: Introductionmentioning
confidence: 99%
“…Balloon assist [5][6][7][8] and stent assist [9][10][11][12] embolization are representative techniques used to treat cerebral aneurysms with wide neck. Although they feature superior efficacy and widespread use, they are implemented in the parent artery rather than the aneurysm.…”
Section: Discussionmentioning
confidence: 99%