2017
DOI: 10.5301/uj.5000240
|View full text |Cite
|
Sign up to set email alerts
|

Safety and Efficacy Outcomes of ZSI 475 Penile Prosthesis

Abstract: ObjectiveThe aim of this study was to demonstrate safety and efficacy of ZSI 475 hydraulic penile prosthesis three components. Preparation, procedure and functional results are similar to AMS 700 and Coloplast Titan. This study was conducted from September 2012 to December 2016.Patients and MethodFrom September 2012 to December 2016, 29 ZSI 475 hydraulic penile prostheses three components were implanted by six surgeons in 28 patients in five European centres. Mean age of patients was 60 years old (44-75). Stan… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(10 citation statements)
references
References 13 publications
1
9
0
Order By: Relevance
“…Worldwide, over the last decades, 3p-IPPs have been produced and marketed by two brands: AMS and Coloplast [ 1 ]. In the recent years, Zephyr surgical implants have been proposed on the market, a new 3p-IPP, the ZSI 475, and some preliminary reports on these devices have been published [ [12] , [13] ].…”
Section: Discussionmentioning
confidence: 99%
“…Worldwide, over the last decades, 3p-IPPs have been produced and marketed by two brands: AMS and Coloplast [ 1 ]. In the recent years, Zephyr surgical implants have been proposed on the market, a new 3p-IPP, the ZSI 475, and some preliminary reports on these devices have been published [ [12] , [13] ].…”
Section: Discussionmentioning
confidence: 99%
“…In one study, the mean time between neophallus construction and prosthesis placement was 3.5 years. 49 The first reported prosthesis placement in a neophallus was described in 1978. 50 In the 1990s, a modified single-cylinder 2-piece Mentor GFS, then later the Ambicor prosthesis was utilized in the neophallus, which provided excellent axial rigidity and avoided a separate reservoir.…”
Section: Safety In Transgender Patientsmentioning
confidence: 99%
“…Few literature is reporting on the use of erectile implants following penis reconstruction in trans men. Specifically, there are several complications associated with implant placement in the reconstructed penis, such as hematoma, infection, urinary fistulas and strictures, partial or total penis necrosis, as well as implant deformity [39][40][41][42].…”
Section: Erection Implantsmentioning
confidence: 99%