2020
DOI: 10.1016/j.hrcr.2020.03.019
|View full text |Cite
|
Sign up to set email alerts
|

Safety and feasibility of radiofrequency redo pulmonary vein isolation ablation for atrial fibrillation after Amulet implantation and device electrical characteristics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 10 publications
0
6
0
Order By: Relevance
“…Unlike the Watchman device, the Amulet device exhibited no cardiac tissue or electrogram recording on its exterior. Anatomical variances do not have a substantial impact on the device's overall efficacy for preventing stroke, and later investigations into incomplete LAAO or peridevice leakage have not demonstrated any substantial increases in long‐term adverse events 39 …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Unlike the Watchman device, the Amulet device exhibited no cardiac tissue or electrogram recording on its exterior. Anatomical variances do not have a substantial impact on the device's overall efficacy for preventing stroke, and later investigations into incomplete LAAO or peridevice leakage have not demonstrated any substantial increases in long‐term adverse events 39 …”
Section: Discussionmentioning
confidence: 99%
“…Anatomical variances do not have a substantial impact on the device's overall efficacy for preventing stroke, and later investigations into incomplete LAAO or peridevice leakage have not demonstrated any substantial increases in long-term adverse events. 39 Postoperative antithrombotic treatment differed for the two devices and for each study. After Amulet installation, patients are commonly instructed to initiate dual antiplatelet treatment followed by single aspirin therapy; Following Watchman implant, patients usually take OAC over 45 days prior switching to dual antiplatelet treatment and then aspirin.…”
Section: Discussionmentioning
confidence: 99%
“…Data regarding this issue are limited. A small number of case reports [ 8 , 9 , 10 ] and case series [ 11 , 12 , 13 , 14 , 15 ] with small samples have been carried out to investigate the feasibility and efficacy of LA CA in patients with LAAO devices. However, most patients in prior studies were implanted with nitinol cage devices (e.g., Watchman).…”
Section: Introductionmentioning
confidence: 99%
“…With increased utilization of LAAO devices, the need for pulmonary vein isolation (PVI) procedures in patients with prior LAAO devices is expected to increase. Several reports have discussed the safety and feasibility of radiofrequency (RF) ablation and cryoablation procedures for this group of patients 3–9 . Complications related to inadvertent ablation over the LAAO device have been associated with RF ablation.…”
Section: Introductionmentioning
confidence: 99%
“…Several reports have discussed the safety and feasibility of radiofrequency (RF) ablation and cryoablation procedures for this group of patients. [3][4][5][6][7][8][9] Complications related to inadvertent ablation over the LAAO device have been associated with RF ablation. Laser balloon (LB) is an efficacious alternative for PVI.…”
Section: Introductionmentioning
confidence: 99%