2013
DOI: 10.2147/opth.s40147
|View full text |Cite
|
Sign up to set email alerts
|

Safety comparison of additives in antiglaucoma prostaglandin (PG) analog ophthalmic formulations

Abstract: PurposeTo investigate the safety of five types of antiglaucoma prostaglandin analog ophthalmic formulations, and to clarify their differences in accordance with contained additives (preservatives and surface-active agents).MethodsThe following five types of ophthalmic solutions and three types of additives were investigated: latanoprost (Xalatan®; latanoprost), tafluprost (Tapros®; tafluprost), bimatoprost (Lumigan®; bimatoprost), travoprost (Travatan®; travoprost), travoprost (Travatan Z®; travoprost-Z), benz… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

1
5
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 12 publications
1
5
0
Order By: Relevance
“…Moreover, according to another report, PI can induce cytotoxicity at concentrations ranging from 5% to 10% in vivo and 0.08% to 0.32% in vitro [20]. Washing rabbit eyes with 1.25% PI results in superficial punctate keratitis [23]. These previous data strongly support our results.…”
Section: Discussionsupporting
confidence: 91%
See 1 more Smart Citation
“…Moreover, according to another report, PI can induce cytotoxicity at concentrations ranging from 5% to 10% in vivo and 0.08% to 0.32% in vitro [20]. Washing rabbit eyes with 1.25% PI results in superficial punctate keratitis [23]. These previous data strongly support our results.…”
Section: Discussionsupporting
confidence: 91%
“…However, this device takes more than 30 min to take a single measurement. We previously developed an electrophysiologic method that uses corneal impedance measurement to quantify corneal barrier function or damage [20, 23, 28]. This method, the CR measurement, has been shown to accurately and quantitatively evaluate fine corneal barrier function not detected by the fluorescein staining method in previous studies using rabbit eyes [12, 22, 28].…”
Section: Discussionmentioning
confidence: 99%
“…We tested our device to measure the corneal resistance (CR) in rabbit eyes and confirmed ocular surface safety with reliable reproducible data. [4][5][6][7] This device enables the quantitative assessment of corneal disease, to objectively confirm its progress by the degree of corneal injury with the passage of time. 4,5 There have been several reports of similar devices in animal eyes, but to date, none in human eyes.…”
mentioning
confidence: 99%
“…This letter is in regards to Fukuda et al1 We thank the authors for their informative contribution. The use of rabbit specimens was relevant to this study as previously alluded to by Wilhelmus, who concluded from his research that rabbit eyes were more susceptible to irritants than human eyes 2…”
mentioning
confidence: 93%
“…The BAK additive could have influenced the results; however the authors did an excellent job of obtaining a more suitable measurement of the corneal damage by developing an apparatus to measure it 1. It would have been ideal if the authors had mentioned the details of the “apparatus,” so as to give the readers a little more information about how objectively the corneal damage was measured.…”
mentioning
confidence: 99%