Safety of Capsule Endoscopy Using Human Body Communication in Patients with Cardiac Devices

Abstract: Capsule endoscopy using human body communication to transmit data was safely performed in patients with cardiac pacemakers or implantable cardiac defibrillators. Images from the capsule endoscopy were not affected by cardiac devices. A further large-scale study is required to confirm the safety of capsule endoscopy with various types of cardiac devices.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0
1

Year Published

2013
2013
2022
2022

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 18 publications
(12 citation statements)
references
References 23 publications
0
11
0
1
Order By: Relevance
“…Additionally, few clinical applications of MiroCam in patients with PM or ICD have been conducted without problems [27]. No reports are as yet available for OMOM capsule.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Additionally, few clinical applications of MiroCam in patients with PM or ICD have been conducted without problems [27]. No reports are as yet available for OMOM capsule.…”
Section: Discussionmentioning
confidence: 99%
“…A modulated 3V current is tapped by standard ECG electrodes that are attached to the patient’s abdomen [26]. Although this principle might be more critical for PM/ICDs than radiotransmission, no interference was observed with MiRoCam and PM/ICD in a recent small series with six patients [27]. No disturbances in cardiac devices or arrhythmias were detected on telemetry monitoring during CE.…”
Section: Ce In Patients With Pmmentioning
confidence: 99%
“…Only one study investigated EMI between the MiroCam endoscope that uses human body communication to transmit data and PMs ( n = 3) and ICDs ( n = 3)[70]. VCE was safely performed in patients with PMs and ICDs, and images from capsule endoscopy were not affected by cardiac devices.…”
Section: Vce In Patients With Implantable Cardiac Devicesmentioning
confidence: 99%
“…Based on these theories, clinical study was conducted in six patients with three pacemakers and three implantable cardiac defibrillators [77]. No disturbance in cardiac devices or arrhythmia was detected on telemetry monitoring during capsule endoscopy.…”
Section: Clinical Studies Of Mirocammentioning
confidence: 99%