SAFIR-I: Design and Performance of a High-Rate Preclinical PET Insert for MRI

Abstract: (1) Background: Small Animal Fast Insert for MRI detector I (SAFIR-I) is a preclinical Positron Emission Tomography (PET) insert for the Bruker BioSpec 70/30 Ultra Shield Refrigerated (USR) preclinical 7T Magnetic Resonance Imaging (MRI) system. It is designed explicitly for high-rate kinetic studies in mice and rats with injected activities reaching 500MBq, enabling truly simultaneous quantitative PET and Magnetic Resonance (MR) imaging with time frames of a few seconds in length. (2) Methods: SAFIR-I has an … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
16
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(17 citation statements)
references
References 39 publications
0
16
0
Order By: Relevance
“…The Small Animal Fast Insert for MRI (SAFIR) collaboration is developing novel Positron Emission Tomography (PET) inserts for a Bruker BioSpec 70/30 Ultra Shield Refrigerated (USR) Magnetic Resonance Imaging (MRI) system [ 1 , 2 ]. The inserts are specified to enable quantitative, truly simultaneous PET/MRI research in mice and rats, with a spatial resolution of around in the center of the Field Of View (FOV), at injected activities extending up to .…”
Section: Introductionmentioning
confidence: 99%
See 4 more Smart Citations
“…The Small Animal Fast Insert for MRI (SAFIR) collaboration is developing novel Positron Emission Tomography (PET) inserts for a Bruker BioSpec 70/30 Ultra Shield Refrigerated (USR) Magnetic Resonance Imaging (MRI) system [ 1 , 2 ]. The inserts are specified to enable quantitative, truly simultaneous PET/MRI research in mice and rats, with a spatial resolution of around in the center of the Field Of View (FOV), at injected activities extending up to .…”
Section: Introductionmentioning
confidence: 99%
“…The inserts are specified to enable quantitative, truly simultaneous PET/MRI research in mice and rats, with a spatial resolution of around in the center of the Field Of View (FOV), at injected activities extending up to . Exploitation of the associated high count rates, specifically the corresponding low noise, enables an exceptional image frame acquisition speed in the order of one diagnostically relevant frame every few seconds [ 1 , 3 , cf.]. This high frame rate is required for capturing fast tracer kinetics, which was not possible with existing small-animal PET systems [ 1 , cf.].…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations