2016
DOI: 10.1589/jpts.28.936
|View full text |Cite
|
Sign up to set email alerts
|

Same-session and between-day intra-rater reliability of hand-held dynamometer measurements of isometric shoulder extensor strength

Abstract: [Purpose] The purpose of present study was to establish the same-session and between-day intra-rater reliability of measurements of extensor strength in the maximum abducted position (MABP) using hand-held dynamometer (HHD). [Subjects] Thirteen healthy volunteers (10 male, 3 female; mean ± SD: age 19.8 ± 0.8 y) participated in the study. [Methods] Participants in the prone position with maximum abduction of shoulder were instructed to hold the contraction against the ground reaction force, and peak isometric f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
13
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(17 citation statements)
references
References 12 publications
3
13
1
Order By: Relevance
“…The results of the present study also showed high intra-rater reliability that was considered ‘almost perfect’. Therefore, consistent with previous studies3 ) , use of the mean of 3 trials is recommended for this measurement method. Regarding the intra-rater measurement error for for extensor strength, Awatani et al3 ) reported that the ICC 1, 2 for between-day data was ≤6.2 N, and using data from the same study, the SEM% was calculated to be 6.7%.…”
Section: Discussionsupporting
confidence: 72%
See 4 more Smart Citations
“…The results of the present study also showed high intra-rater reliability that was considered ‘almost perfect’. Therefore, consistent with previous studies3 ) , use of the mean of 3 trials is recommended for this measurement method. Regarding the intra-rater measurement error for for extensor strength, Awatani et al3 ) reported that the ICC 1, 2 for between-day data was ≤6.2 N, and using data from the same study, the SEM% was calculated to be 6.7%.…”
Section: Discussionsupporting
confidence: 72%
“…Therefore, consistent with previous studies3 ) , use of the mean of 3 trials is recommended for this measurement method. Regarding the intra-rater measurement error for for extensor strength, Awatani et al3 ) reported that the ICC 1, 2 for between-day data was ≤6.2 N, and using data from the same study, the SEM% was calculated to be 6.7%. The coefficients of variation (CVs) of the SEM and SEM% were the same8 ) , and the common analytical goal for the CV is ≤10%9 ) .…”
Section: Discussionsupporting
confidence: 72%
See 3 more Smart Citations