Sample introduction systems for the analysis of liquid microsamples by ICP-AES and ICP-MS

Abstract: There are many fields in which the available sample volume

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
94
0
1

Year Published

2008
2008
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 133 publications
(96 citation statements)
references
References 237 publications
(390 reference statements)
1
94
0
1
Order By: Relevance
“…The mass spectrometer increases sensitivity [2]. The mass spectrometer splits the ionic species according to their mass/charge proportionality [28,33]. The main disadvantage concerns matrix effects (non-spectroscopic interferences) which are produced by electrostatic effects in the generation stage of the aerosol.…”
Section: Inductively Coupled Plasma Mass Spectrometry (Icp-ms)mentioning
confidence: 99%
“…The mass spectrometer increases sensitivity [2]. The mass spectrometer splits the ionic species according to their mass/charge proportionality [28,33]. The main disadvantage concerns matrix effects (non-spectroscopic interferences) which are produced by electrostatic effects in the generation stage of the aerosol.…”
Section: Inductively Coupled Plasma Mass Spectrometry (Icp-ms)mentioning
confidence: 99%
“…Furthermore, it can determine the amount of sample needed. Conventional pneumatic nebulisers (concentric or cross flow), which are often used for Pt or Ru analysis (Nygren et al, 1990;Allain et al, 1992;Perry & Balazs, 1994;Gamelin et al, 1995;Morazzoni et al, 1995;Azim-Araghi et al, 2001;Liu et al, 2002a;John et al, 2003) operate at a flow rate of 0.5-1 mL/min (Todoli & Mermet, 2006). The high flow rate in combination with the time required to carry out a complete signal reading (1-5 min), requires a high sample volume (>1 mL).…”
Section: Instrumental Adjustmentsmentioning
confidence: 99%
“…This method is associated with high sample consumption (>0.3 ml min -1 ) 2 and an incomplete sample transport. Thus, it becomes impractical for applications where only microliter sample volumes are available, as in biological, forensic, toxicological and clinical studies 3 . To reduce the sample consumption, nebulizers with smaller nozzle dimensions were developed 3 .…”
Section: Introductionmentioning
confidence: 99%
“…Thus, it becomes impractical for applications where only microliter sample volumes are available, as in biological, forensic, toxicological and clinical studies 3 . To reduce the sample consumption, nebulizers with smaller nozzle dimensions were developed 3 . However, the reduced nozzle size increases the risk of clogging when samples of undigested biological fluids or concentrated salt solutions have to be analyzed 3 .…”
Section: Introductionmentioning
confidence: 99%