2011
DOI: 10.1021/ef200811q
|View full text |Cite
|
Sign up to set email alerts
|

Sampling and Online Analysis of Alkalis in Thermal Process Gases with a Novel Surface Ionization Detector

Abstract: When using biomass or waste as a feedstock for power production, alkalis are a major concern because of their negative effects on equipment. To investigate the release behavior of alkalis and the effectiveness of countermeasures, it is indispensable to quantify alkali emissions with a high time resolution (less than 1 min). This paper presents a newly developed alkali detector based on the principle of surface ionization. The detector includes a number of improvements compared to previous designs that enable a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
32
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 39 publications
(32 citation statements)
references
References 35 publications
0
32
0
Order By: Relevance
“…The nebulizing efficiency is measured as mass flow output of analyte per mass flow input of the analyte. For the parameter settings of the USN used in this study an efficiency of 10% has been determined (Wellinger et al, 2011). The analysis of peaks using a background correction that automatically corrects for changes in the level of background noise (Poole et al, 2005).…”
Section: Icp-oesmentioning
confidence: 99%
See 3 more Smart Citations
“…The nebulizing efficiency is measured as mass flow output of analyte per mass flow input of the analyte. For the parameter settings of the USN used in this study an efficiency of 10% has been determined (Wellinger et al, 2011). The analysis of peaks using a background correction that automatically corrects for changes in the level of background noise (Poole et al, 2005).…”
Section: Icp-oesmentioning
confidence: 99%
“…The gaseous particles that enter the condensation interface are limited in their growth by rapid quench with cold argon gas in excess, which generates aerosols suitable to transportation through sampling lines. For a more detailed description of the gas quench system see Wellinger et al, 2011.…”
Section: Gas Quench Measurementsmentioning
confidence: 99%
See 2 more Smart Citations
“…Pressure reduction, gas dilution, or some other means to reduce the dew point of tar compounds is generally required to avoid analyte condensation prior to reaching the analytical device [22,24,25]. One recently developed technique immediately quenches the heated slipstream with an alcohol to form a biphasic mixture of analytes: a non-condensable gas stream free of particulates and heavy tars that can be analyzed by micro-GC, and a liquid phase that can be analyzed using on-line density measurements for water concentration and UV-vis spectroscopy to provide real time tar concentration [22,25].…”
Section: Syngas and Tar Analytical Techniquesmentioning
confidence: 99%