2019
DOI: 10.1080/02786826.2018.1559919
|View full text |Cite
|
Sign up to set email alerts
|

Sampling efficiency of low-volume PM10 inlets with different impaction substrates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 20 publications
(9 citation statements)
references
References 29 publications
0
9
0
Order By: Relevance
“…An M-PM 10 impactor with oil-soaked GFF substrate supported by a porous metal disc as shown in Fig. 2 was designed to avoid the particle bounce and overloading effects (Le T.C. et al, 2019).…”
Section: Particle Loading Effectmentioning
confidence: 99%
See 2 more Smart Citations
“…An M-PM 10 impactor with oil-soaked GFF substrate supported by a porous metal disc as shown in Fig. 2 was designed to avoid the particle bounce and overloading effects (Le T.C. et al, 2019).…”
Section: Particle Loading Effectmentioning
confidence: 99%
“…Since 1970 until now, inertial impactors have been used extensively for various purposes such as (i) size-based classification for mass concentration measurement (Le T.C. and Tsai C.J., 2017;Le T.C. et al, 2019), (ii) particle mass distribution measurement (Marple V.A.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Two porous metal discs and three filter holders were removed for testing the penetration curve of the cyclone, and then the cyclone and the three filter holders were removed for testing the particle loss of the porous metal discs. Figure 2 shows the experimental setup of the cyclone penetration curve and the PDS particle loss tests with the method shown in the previous studies [53,54]. A vibrating orifice aerosol generator (VOAG, TSI Model 3450, USA) was used to generate monodisperse NaCl particles ranging from 1.20 to 5.05 µm and an aerodynamic particle sizer (APS, model 3321, TSI Incorporated, St. Paul, MN, USA) was used to measure the upstream and downstream particle concentrations.…”
Section: Five Liters Per Minute Pds Design and Laboratory Testmentioning
confidence: 99%
“…The PPWD-PILS-IC monitoring system was presented in detail in Li et al [31] and is described briefly below. A 16.7 L/min EPA PM 10 inlet [54] and a PM 2.5 VSCC inlet (very sharp cut cyclone) were used to remove particles larger than 2.5 µm in aerodynamic diameter. Sample air was drawn through the PPWD at 12.3 L/min to capture water-soluble precursor gases [36,37] first, before being introduced into the PILS to collected WSI ions [38].…”
Section: Field Comparison Testmentioning
confidence: 99%