2021
DOI: 10.1016/j.xrrt.2021.01.003
|View full text |Cite
|
Sign up to set email alerts
|

Scapulothoracic fusion using nonabsorbable suture fixation: surgical technique and review of the literature

Abstract: Background: Historically, scapulothoracic fusion (STF) is performed using steel wire and plate construct fixation. The purpose of this study is to report a recent fusion achieved through ultra-high-molecularweight polyethylene-reinforced suture fixation as well as to perform a systematic literature review of techniques, fusion rates, complications, and reoperation. Methods: Patient data were gathered from chart review and clinical encounters. For the review, MED-LINE, Embase, and Ovid databases were queried fo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 32 publications
0
3
0
Order By: Relevance
“…The ribs are trimmed in the CAD software coronally and sagittally only to contain the portions that contact the scapula to decrease the simulation time (Figure 1A). Only ribs 2 through 7 are included in the initial model since only those ribs have been used for the STA procedure in the literature 10 …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The ribs are trimmed in the CAD software coronally and sagittally only to contain the portions that contact the scapula to decrease the simulation time (Figure 1A). Only ribs 2 through 7 are included in the initial model since only those ribs have been used for the STA procedure in the literature 10 …”
Section: Methodsmentioning
confidence: 99%
“…Only ribs 2 through 7 are included in the initial model since only those ribs have been used for the STA procedure in the literature. 10 2.2 | Computational simulations…”
Section: D Model Of Scapula and Ribsmentioning
confidence: 99%
“…Multifilament metal cables are reliable implants, but prominent crimps that are used to secure loops may cause skin irritation and may require removal. Recently, a high-strength suture fixation method has also been proposed ( 58 ). Currently, there is no study on the efficacy of this fixation method, and it is a matter of debate if they preserve the initial compression or not.…”
Section: Authors’ Preferred Techniquementioning
confidence: 99%