2005
DOI: 10.1080/10448630500454445
|View full text |Cite
|
Sign up to set email alerts
|

Scientific Reviews: Microstrip Gas Chambers (MSGC) for Future Neutron Instrumentation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0
1

Year Published

2007
2007
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 16 publications
(13 reference statements)
0
4
0
1
Order By: Relevance
“…Such potential charging up is not expected under the proposed conditions of EL in liquid with an optional small (< 10) charge gain. The active area of MSGC detectors reaches 240 × 240 mm 2 [62]. For a MSP review see [61].…”
Section: Single-phase Detectors With Micro Strip Plate (Msp) Multipliersmentioning
confidence: 99%
“…Such potential charging up is not expected under the proposed conditions of EL in liquid with an optional small (< 10) charge gain. The active area of MSGC detectors reaches 240 × 240 mm 2 [62]. For a MSP review see [61].…”
Section: Single-phase Detectors With Micro Strip Plate (Msp) Multipliersmentioning
confidence: 99%
“…A detector based on the MSGC-technology and a curved-MWPC similar to those used at the D20 [35] or D1B instruments [27], respectively, also meet the requirements in terms of pixel size and count rate capability. However, both technologies would require a significant amount of R&D and engineering work in order to increase the angular coverage in the vertical direction, which is now limited to 40 [34] and 20 cm [64], respectively. But, more importantly, the unclear unavailability of the 3 He gas in the future represents a high risk for the ESS science program [65,66].…”
Section: Strategy For the Diffraction Detectors At The Essmentioning
confidence: 99%
“…Moreover, the required sensitive area does not exceed 1 m 2 per detector. Thus, the need for high-efficiency, high-granularity SANS detectors could, in principle, be satisfied with the existing technologies such as the medium-size 3 He-filled MWPCs similar to those operational at the REFSANS instrument at MLZ Garching [68], the SANS beamline at the BNC [69] or the D16 instrument at ILL [30,31], a MSGC-based detector [34] or even square-shaped position sensitive-tubes (PSD) in a monoblock design [70].…”
Section: Jinst 12 P01019mentioning
confidence: 99%
See 1 more Smart Citation
“…В ILL создавались первоклассные дифракционные приборы с позиционно-чувствительными детекторами как на MWPC, так и на MSGC. За 20 лет создано более десяти дифракционных приборов, построенных на MSGC [20,[30][31][32][33], которые успешно работают до настоящего времени. В качестве примера приведем дифрактометр D20.…”
unclassified