2011
DOI: 10.1118/1.3539725
|View full text |Cite
|
Sign up to set email alerts
|

GPUMCD: A new GPU‐oriented Monte Carlo dose calculation platform

Abstract: Purpose : Monte Carlo methods are considered the gold standard for dosimetric computations in radiotherapy. Their execution time is however still an obstacle to the routine use of Monte Carlo packages in a clinical setting. To address this problem, a completely new, and designed from the ground up for the GPU, Monte Carlo dose calculation package for voxelized geometries is proposed: GPUMCD.Method : GPUMCD implements a coupled photon-electron Monte Carlo simulation for energies in the range 0.01 MeV to 20 MeV.… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
199
0
3

Year Published

2014
2014
2020
2020

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 194 publications
(205 citation statements)
references
References 52 publications
3
199
0
3
Order By: Relevance
“…Recently, a new commercial GPU‐based Monte Carlo dose calculation algorithm (GPUMCD) 10 , 11 has been proposed by the vendor Elekta (Elekta AB, Stockholm, Sweden) and is available in the research version of the Monaco TPS. The Monaco TPS currently has a clinical MC dose calculation algorithm called XVMC (12) for photons, which is founded on the voxel‐based MC algorithm (VMC) (13) for electron beams.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, a new commercial GPU‐based Monte Carlo dose calculation algorithm (GPUMCD) 10 , 11 has been proposed by the vendor Elekta (Elekta AB, Stockholm, Sweden) and is available in the research version of the Monaco TPS. The Monaco TPS currently has a clinical MC dose calculation algorithm called XVMC (12) for photons, which is founded on the voxel‐based MC algorithm (VMC) (13) for electron beams.…”
Section: Introductionmentioning
confidence: 99%
“…Finally, in terms of computational time the current performance of the GaTE MCs platform is not compatible with a potential clinical use, even if one considers the use of pre-operative CT imaging and subsequent treatment planning. However, the necessary computational times are expected to be dramatically reduced in the future by using hybrid computing architectures, such as graphical card units (GPUs), including recently proposed implementations for Geant4 based MCss both in imaging and radiotherapy applications [23][24][25].…”
Section: Discussionmentioning
confidence: 99%
“…Monte Carlo methods are considered the gold standard for dose calculations in radiotherapy [20,37]. Their computation complexity is, however, an obstacle to the routine use of Monte Carlo in a clinical setting, although signicant advances have been made by using variance reduction techniques and taking advantage of the graphical processing unit (GPU) to speed up computations [31].…”
Section: Dose Calculationsmentioning
confidence: 99%