2020
DOI: 10.1002/2050-7038.12616
|View full text |Cite
|
Sign up to set email alerts
|

MMC‐HVDC system oscillation suppression control strategy based on state feedback decoupling control

Abstract: Summary Background: Subsynchronous oscillation (SSO) of wind farm integration through modular multi‐level converter‐based high voltage direct current (MMC‐HVDC) transmission system puts forward high requirements for the robustness of MMC control strategy and parameters, which is the key problem to be solved in SSO suppression. This paper proposes a method to suppress the oscillation in wind farm integration through modular multi‐level converter‐based high voltage direct current (MMC‐HVDC) transmission system. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
2
1
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 21 publications
(20 reference statements)
0
2
0
Order By: Relevance
“…The grid voltages and line currents are measured and the positive and negative components are separated and transformed into their dq component using PLL. Then i ± dq are introduced to current controller, in this case a Dual Synchronously Rotating Reference Frame (DSRF) current controllers is proposed to control both positive and negative sequence currents [38]- [42]. It consists of two identical vector current controllers for positive and negative sequence currents.…”
Section: Instantaneous Active Reactive Control (Iarc)mentioning
confidence: 99%
“…The grid voltages and line currents are measured and the positive and negative components are separated and transformed into their dq component using PLL. Then i ± dq are introduced to current controller, in this case a Dual Synchronously Rotating Reference Frame (DSRF) current controllers is proposed to control both positive and negative sequence currents [38]- [42]. It consists of two identical vector current controllers for positive and negative sequence currents.…”
Section: Instantaneous Active Reactive Control (Iarc)mentioning
confidence: 99%
“…Nowadays, the MMC system is adopted in the Zhoushan MTDC project, Xiamen ±320 kv DC project, Luxi HVDC project, and Zhangbei DC project. It is noteworthy that the MMCs in all of these projects adopt conventional MMC with half‐bridge submodules (HBSMs) 3‐5 …”
Section: Introductionmentioning
confidence: 99%