1994
DOI: 10.1007/bf01192843
|View full text |Cite
|
Sign up to set email alerts
|

Screening analysis of pesticide residues in plant foodstuffs by capillary gas chromatography using the DFG multiresidue method S19: a comparison of customory detection by ECD/NPD with the novel atomic emission detector (AED)

Abstract: Over a period of 7 months nearly 240 plant foodstuffs taken fresh from the market were analysed for pesticide residues using the Deutsche Forschungsgemeinschaft (DFG) multiresidue method (MRM) S19. The analysed foodstuffs were a representative cross-section of different fruits and vegetables offered on sale on the German market. With the slightly modified MRM S19, up to 400 pesticides and metabolites amenable to gas chromatography (GC) can be determined. The screening analysis was performed with the combinatio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1996
1996
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(3 citation statements)
references
References 16 publications
0
3
0
Order By: Relevance
“…Golden Delicious of medium size (70–85 mm) and free of visual defects were pooled, immediately transported to the laboratory, and cut into small pieces using a cutter (Hobart model 84181D, Milano, Italy). 100 g of the fruit sample was homogenized and extracted with acetone (200 mL) using an Ultra-Turrax T25 digital mixer (IKA, Milano, Italy) for 2 min at room temperature . The extract was filtered, and an aliquot (50% of the extract) was diluted with brine (40 mL) and extracted twice with dichloromethane (70 mL each).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Golden Delicious of medium size (70–85 mm) and free of visual defects were pooled, immediately transported to the laboratory, and cut into small pieces using a cutter (Hobart model 84181D, Milano, Italy). 100 g of the fruit sample was homogenized and extracted with acetone (200 mL) using an Ultra-Turrax T25 digital mixer (IKA, Milano, Italy) for 2 min at room temperature . The extract was filtered, and an aliquot (50% of the extract) was diluted with brine (40 mL) and extracted twice with dichloromethane (70 mL each).…”
Section: Methodsmentioning
confidence: 99%
“…100 g of the fruit sample was homogenized and extracted with acetone (200 mL) using an Ultra-Turrax T25 digital mixer (IKA, Milano, Italy) for 2 min at room temperature. 20 The extract was filtered, and an aliquot (50% of the extract) was diluted with brine (40 mL) and extracted twice with dichloromethane (70 mL each). The combined organic layer was dried with anhydrous sodium sulfate, and the solvent was evaporated in vacuo after filtration.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…Since almost all pesticides contain heteroatoms, element-specific detection techniques such as atomic emission detectors (AED) are often utilized for pesticide detection after capillary GC separation. [130][131][132] Its overall low sensitivity as well as its matrix susceptibility represent the main drawbacks of AED as a (hetero)element specific detector. 133 Here ICP-MS represents a powerful alternative due to its special properties.…”
Section: Trends In Applying Icp-ms For Quantitative Analysismentioning
confidence: 99%