Screening the low molecular weight fraction of human serum using ATR-IR spectroscopy

Abstract: Vibrational spectroscopic techniques can detect small variations in molecular content, linked with disease, showing promise for screening and early diagnosis. Biological fluids, particularly blood serum, are potentially valuable for diagnosis purposes. The so-called Low Molecular Weight Fraction (LMWF) contains the associated peptidome and metabolome and has been identified as potentially the most relevant molecular population for disease-associated biomarker research. Although vibrational spectroscopy can del… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
45
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 56 publications
(48 citation statements)
references
References 47 publications
2
45
0
Order By: Relevance
“…Figure 2 presents the dependence of the area under the curve observed in raw data (AUC -between baseline and peak maximum), calculated for the band 1180-955 cm -1 , depending on deposited volume, for two different concentrations of glucose solution. The 10 g.dL -1 solution does not exhibit any noticeable decrease in the AUC between 0.5 µL and 2µL, explained by a full coverage of the crystal coupled to a saturation of the signal 24 . The notion of saturation is defined by the loss of linearity between the absorbance and the concentrations measured.…”
Section: Data Pre-processing and Analysismentioning
confidence: 85%
See 4 more Smart Citations
“…Figure 2 presents the dependence of the area under the curve observed in raw data (AUC -between baseline and peak maximum), calculated for the band 1180-955 cm -1 , depending on deposited volume, for two different concentrations of glucose solution. The 10 g.dL -1 solution does not exhibit any noticeable decrease in the AUC between 0.5 µL and 2µL, explained by a full coverage of the crystal coupled to a saturation of the signal 24 . The notion of saturation is defined by the loss of linearity between the absorbance and the concentrations measured.…”
Section: Data Pre-processing and Analysismentioning
confidence: 85%
“…In the present study, a 10 kDa centrifugal device was used in order to specifically deplete the abundant proteins such as globulins and albumin 24 and retain only the molecular species with low molecular weight in the filtrate, below the cut off point of the membrane, for subsequent spectroscopic analysis. For instance, glucose is about 180 Daltons, which means it will freely pass through the membrane during spinning of the human serum.…”
Section: 1d Summary Of Results: 10 Kda Filtered Human Serum Spikedmentioning
confidence: 99%
See 3 more Smart Citations