2015
DOI: 10.1016/j.egypro.2015.11.832
|View full text |Cite
|
Sign up to set email alerts
|

Seasonal Performance Analysis of a Residential Heat Pump Using Different Fluids with Low Environmental Impact

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 7 publications
0
6
0
Order By: Relevance
“…It is also important to highlight that the best COP of the R290 compared with the R1234yf was found in the results presented by Makhnatch and Khodabandeh (2014b), Ghoubali et al (2014) and Botticella and Viscito (2015) for different systems.…”
Section: Coaxial Condensermentioning
confidence: 72%
See 3 more Smart Citations
“…It is also important to highlight that the best COP of the R290 compared with the R1234yf was found in the results presented by Makhnatch and Khodabandeh (2014b), Ghoubali et al (2014) and Botticella and Viscito (2015) for different systems.…”
Section: Coaxial Condensermentioning
confidence: 72%
“…These refrigerants will be compared to R134a, which is widely used in DX-SAHP (Hawlader et al, 2001;Chyng et al, 2003;Chata et al, 2005;Chow et al, 2010;Fernández-Seara et al, 2012;Sun et al, 2014;Moreno-Rodriguez et al, 2013;Deng and Yu, 2016;Diniz, 2017;Kong et al, 2018a;Kong et al, 2018b). The R290 was selected because of the discussions presented in Sarbu (2014), Makhnatch and Khodabandeh (2014b), Ghoubali et al (2014) and Botticella and Viscito (2015). In addition, the R290 is used by many heat pump manufactures (Palm, 2008) and it can work at high evaporating temperature (Chaichana et al, 2003).…”
Section: Selecting Refrigerants Candidatesmentioning
confidence: 99%
See 2 more Smart Citations
“…It consists of a 1D cell-by-cell discretization method that divides the heat exchanger into n cells, applies the energy conservation equation to each cell, and solves iteratively until convergence in the heat transfer area is reached; further details of this method can be found in [33]. On the other hand, since the condenser of the auxiliary R1234yf cycle is a conventional water/subcritical refrigerant plate heat exchanger, a well-known commercial software, IMST-ART [40], extensively used by several authors in their research work [41][42][43][44][45][46] as a simulation tool to model refrigeration cycle components, including different types of heat exchangers, has been used to obtain condensation pressure and heat transfer rate. The same method has been used to model the evaporator of the auxiliary cycle for Conf.…”
Section: Numerical Modelmentioning
confidence: 99%