2015
DOI: 10.1007/s10570-015-0694-z
|View full text |Cite
|
Sign up to set email alerts
|

SEC–MALLS analysis of wood holocelluloses dissolved in 8 % LiCl/1,3-dimethyl-2-imidazolidinone: challenges and suitable analytical conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 28 publications
0
3
0
Order By: Relevance
“…Other SEC attachments and the operation conditions are described elsewhere. 19,20 The dn/dc value of each polymer or cellobiose was obtained from the SEC/MALLS/RI data using the attached software according to eq 1, assuming 100% mass recovery. This method requires accurate injection volumes and sample concentrations, and also needs all sample molecules to be eluted off the column.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Other SEC attachments and the operation conditions are described elsewhere. 19,20 The dn/dc value of each polymer or cellobiose was obtained from the SEC/MALLS/RI data using the attached software according to eq 1, assuming 100% mass recovery. This method requires accurate injection volumes and sample concentrations, and also needs all sample molecules to be eluted off the column.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…The SEC/MALLS/RI analysis system comprising a SEC column (KD-806M, Shodex, Japan), a MALLS detector (DAWN HELEOS-II, λ = 658 nm, Wyatt Technologies, USA), and an RI detector (RID-10A, Shimadzu, Japan), and 1.0% w/v LiCl/DMAc, 0.5% w/v LiCl/DMAc, or 1.0% w/v LiCl/DMI was used as eluents. Other SEC attachments and the operation conditions are described elsewhere. , The d n /d c value of each polymer or cellobiose was obtained from the SEC/MALLS/RI data using the attached software according to eq , assuming 100% mass recovery. This method requires accurate injection volumes and sample concentrations, and also needs all sample molecules to be eluted off the column. where α is a RI detector instrument constant, W injected is the injected mass, ∑Δ v i is the volume of the slice, and V i and V baseline are the RI signal and baseline voltages, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…Moreover, MALLS provides structural information, such as radii of gyration . Because of its easy realization, GPC–MALLS has been widely applied to determine absolute molecular weight of starches, proteins, celluloses, synthetic polymers, and so forth.…”
Section: Introductionmentioning
confidence: 99%