2022
DOI: 10.1016/j.jcoa.2022.100062
|View full text |Cite
|
Sign up to set email alerts
|

Second dimension temperature programming system for comprehensive two-dimensional gas chromatography with true temperature control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
10
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(10 citation statements)
references
References 19 publications
0
10
0
Order By: Relevance
“…Temperature versus Resistance Calibration. With the previous version of the 2 DTPS, 13 the temperature differential between the 2 D column and the oven was measured directly using a differential thermocouple system, which required calibration by setting the GC oven to discrete temperatures. This was due to the GC oven temperature not being measured by the Arduino microcontroller.…”
Section: Column Mounting Hardware and Connectionmentioning
confidence: 99%
See 2 more Smart Citations
“…Temperature versus Resistance Calibration. With the previous version of the 2 DTPS, 13 the temperature differential between the 2 D column and the oven was measured directly using a differential thermocouple system, which required calibration by setting the GC oven to discrete temperatures. This was due to the GC oven temperature not being measured by the Arduino microcontroller.…”
Section: Column Mounting Hardware and Connectionmentioning
confidence: 99%
“…However, passive cooling by keeping the 2 D column inside the GC oven was sufficient and reduced complexity. 13 Cai and Stearns utilized a collinear heating design, where the 2 D fused silica column and a parallel nickel heating/sensing wire were wrapped together to form a tight bundle. This bundle was mounted on top of the GC, where compressed air controlled by a solenoid valve was used to cool the 2 D column bundle.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…5 In our earlier work, a custom-made true second-dimension temperature programming system ( 2 DTPS) was introduced for the first time to combat the general elution problem. 6 In the first part of this paper, a modified system which utilized a commercial stainless-steel column in the 2 D for sample separation, heating, and temperature measurement has been described. 7 Direct resistive heating of the 2 D column made it possible to temperature program and cool the column in the short time frame of the modulation period.…”
mentioning
confidence: 99%
“…To demonstrate the compatibility with typical GC × GC setups, , the 2 DTPS was tested with a reversed-flow differential flow modulator and a time-of-flight mass spectrometer (TOFMS). Both the flow modulator , and TOFMS result in substantially different 2 D separation conditions compared to the thermal modulator and FID tested before with the 2 DTPS. , The effect of the 2 D flow fluctuations caused by the rapid 2 D column heating and cooling on the mass spectra was examined. This was critical in demonstrating the system’s compatibility with the extremely powerful GC × GC–MS separation technique.…”
mentioning
confidence: 99%