2017
DOI: 10.1007/s12551-017-0374-3
|View full text |Cite
|
Sign up to set email alerts
|

Sedimentation velocity analytical ultracentrifugation for characterization of therapeutic antibodies

Abstract: Sedimentation velocity analytical ultracentrifugation (SV-AUC) coupled with direct computational fitting of the observed concentration profiles (sedimentating boundary) have been developed and widely used for the characterization of macromolecules and nanoparticles in solution. In particular, size distribution analysis by SV-AUC has become a reliable and essential approach for the characterization of biopharmaceuticals including therapeutic antibodies. In this review, we describe the importance and advantages … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(23 citation statements)
references
References 52 publications
0
23
0
Order By: Relevance
“…We used an RNA that was smaller than our constructs (74nt tRNA), and another, which was larger, (23S rRNA) to represent a relative difference in RNA size ( Figure 2B), (Table 1). We further employed SV experiments using analytical ultracentrifugation to determine the composition and anisotropy of biomolecules in solution [56,61,62]. Figure 2 presents the sedimentation coefficient distribution of SEC-purified RNA preparation.…”
Section: Discussionmentioning
confidence: 99%
“…We used an RNA that was smaller than our constructs (74nt tRNA), and another, which was larger, (23S rRNA) to represent a relative difference in RNA size ( Figure 2B), (Table 1). We further employed SV experiments using analytical ultracentrifugation to determine the composition and anisotropy of biomolecules in solution [56,61,62]. Figure 2 presents the sedimentation coefficient distribution of SEC-purified RNA preparation.…”
Section: Discussionmentioning
confidence: 99%
“…In this study, we used AUC for characterizing the aggregation states of the mutants, because it is considered as a powerful and accurate method that reliably detects aggregates without the need of interacting matrices. Indeed, size exclusion chromatography (SEC) often fails to detect the actual aggregate contents due to their interaction with the SEC-column matrix [34,35].…”
Section: Biophysical Characterization Of the Tagged Bptismentioning
confidence: 99%
“…The resolution of the denaturing gel was not enough to discern the difference in molecular weights between MVEV (~32 kDa) and PowV (~37kDa) RNA constructs (Table 1). Therefore, we employed sedimentation velocity experiments using analytical ultracentrifuge which determines the composition and anisotropy of biomolecules in solution [50,54,55]. Figure 3 presents the sedimentation coefficient distribution of SEC-purified RNA preparation.…”
Section: Discussionmentioning
confidence: 99%