Sehschärfebestimmung nach Europäischer Norm: wissenschaftliche Grundlagen und Möglichkeiten der automatischen Messung

Abstract: PSYCHOMETRIC FUNCTION: According to the European standard EN ISO 8596 the Landolt-C in 8 different orientations has to be used to measure visual acuity. With decreasing size of the Landolt-C the hit rate declines from 100% to the chance level of 12.5%. This gradual transition is described by the "psychometric function". The steepest point of the psychometric function is in the middle between 100 and 12.5, i.e., at 56.25%. This point of the psychometric function (approximated by 5 of 8 Landolt-Cs) has been sele… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
0
17

Year Published

2004
2004
2024
2024

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 91 publications
(43 citation statements)
references
References 14 publications
0
26
0
17
Order By: Relevance
“…Interrelationships between variables were assessed by calculating correlation coefficients according to Spearman/PeaMAR. In relation to the MARAN (adjusted meter vision) protocol, light perception was added as 2.1 logMAR, hand motion as 2.0 logMAR, and counting fingers as 1.9 logMAR [17]. …”
Section: Methodsmentioning
confidence: 99%
“…Interrelationships between variables were assessed by calculating correlation coefficients according to Spearman/PeaMAR. In relation to the MARAN (adjusted meter vision) protocol, light perception was added as 2.1 logMAR, hand motion as 2.0 logMAR, and counting fingers as 1.9 logMAR [17]. …”
Section: Methodsmentioning
confidence: 99%
“…Fur diese Studie haben wir nur die Werte der postoperativen 4-Monats-and 4-Jahres-Kontrolle mit den praoperativen Werten verglichen. Die Visusprufung erfolgte mit Zahlenoptotypen, die in ihrer Abstufung der EN-ISO-8596-Norm entsprachen [19,20]. Bei 5 Patientenaugen (20,8%) entwickelte sich im Nachbeobachtungszeitraum eine Sehverschlechterung durch Katarakt, die noch vor der 4-Jahres-Kontrolle durch Kataraktoperation behoben wurde.…”
Section: Materials and Methodenunclassified
“…Missed letters in this line were added to the score, letters read on the following smaller line were subtracted from the score. Correctly read 5 letters on the largest line corresponded to 1.0 log MAR or 0.1 in decimal visual acuity; 0.0 log MAR means 1.0 in decimal visual acuity (for example, 2 missed letters at 4 m distance in the log MAR 0.8 line means log MAR 0.84, or 2 additional letters in the next line log MAR 0.76) [4, 5]. …”
Section: Methodsmentioning
confidence: 99%