“…With the nonlinear fitting approach, the confinement coefficient (k) can be expressed as follows. = 0.59 exp (− 0.44 ) + 0.42 (5) where is confinement coefficient and is the eccentric ratio of CFSST columns. Based on the stress-strain model proposed by Tao et al [24], a new three-stage constitutive model which considered the influence of eccentric loading was proposed.…”
Section: Fea Modelingmentioning
confidence: 99%
See 1 more Smart Citation
“…With the nonlinear fitting approach, the confinement coefficient (k) can be expressed as follows. = 0.59 exp (− 0.44 ) + 0.42 (5) where is confinement coefficient and is the eccentric ratio of CFSST columns. Based on the stress-strain model proposed by Tao et al [24], a new three-stage constitutive model which considered the influence of eccentric loading was proposed.…”
Section: Fea Modelingmentioning
confidence: 99%
“…Numerous tests have illustrated that CFST columns have both higher strength and ductility under compressive loading when compared with traditional steel reinforced concrete columns [1]. In current international practices, CFST columns have been widely applied as vertical loadbearing components in high-rise structures, bridges, and ocean infrastructures [2][3][4][5].…”
Section: Introductionmentioning
confidence: 99%
“…e RC slab was bonded to the steel girder using shear studs. en, in the FE model, the Timoshenko beam elements B31 were used to simulate the shear studs, and the interaction between the shear stud and the steel beam was simplified with the nonlinear spring elements * SPRING2 [12]. en, during the model establishment process, the Beam-31 shear stud elements were positioned at the location of the shear studs and embedded into the concrete slab.…”
Section: Element Typesmentioning
confidence: 99%
“…When the girder dimension is close to the column diameter, the flange part inside the tube may interfere with the concrete filling in the CFST column and thus weaken the load bearing and bending performance of the CFST column. To address this problem, Zhou et al [12] proposed a modified through-core detail in which the flange width of the through girder within the column region was reduced to provide space for the concrete to pass as shown in Figure 1. However, in this way, the load transferring ability of the steel girder was reduced.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation