“…Electrocardiographic signals were recorded using CED 1902 and 1401 hardware and fed into Spike 2 software (Cambridge Electronic Design Ltd; Cambridge UK) applying a 10Hz high bandpass filter and 100 Hz low bandpass filter [ 38 ]. For the analysis, a threshold was applied to isolate R-wave peaks and to extract the number of heartbeats in a given time interval.…”
Section: Methodsmentioning
confidence: 99%
“…Electrocardiographic signals were recorded using CED 1902 and 1401 hardware and fed into Spike 2 software (Cambridge Electronic Design Ltd; Cambridge UK) applying a 10Hz high bandpass filter and 100 Hz low bandpass filter [ 38 ]. For the analysis, a threshold was applied to isolate R-wave peaks and to extract the number of heartbeats in a given time interval.…”
Section: Methodsmentioning
confidence: 99%
“…The majority of the ECG signal power is within the 0.5 to 40 Hz range and the filter corner frequencies are chosen to match the specifications recommended by the American Heart Association, the American College of Cardiology and the Heart Rhythm Society [ 31 ] and to minimize uncertainty in the measurement of the R-R peak intervals used to calculate the HR [ 32 ]. Figure 7 b shows that the peak at 50 Hz which represents the mains electrical hum, in our measurements, the system-induced power line noise is reduced by 40 dB and the subsequent peak at 100 Hz is also not present.…”
Section: Methodsmentioning
confidence: 99%
“…Confidence judgements were taken at the end of each trial, participants being asked to rate the confidence they had in their reported number of heartbeats. [30]. For the analysis, a threshold was applied to isolate R-wave peaks and to extract the number of heartbeats in a given time interval.…”
Section: Interoceptive Accuracy and Awarenessmentioning
confidence: 99%