2014
DOI: 10.1039/c4ay01823k
|View full text |Cite
|
Sign up to set email alerts
|

Selective determination of sulphide based on photoluminescence quenching of MPA-capped CdTe nanocrystals by exploiting a gas-diffusion multi-pumping flow method

Abstract: The selective determination of S2-based on photoluminescence quenching of CdTe nanocrystals following gaseous diffusion within a pulsed flow system.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
10

Relationship

3
7

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 49 publications
0
5
0
Order By: Relevance
“…variate calibrations, 164 or fluorimetric determination exploiting a gas-diffusion separation and quantum dot nanocrystals for detection. 165 Another smart and widely recognized approach to enhancing the solutions pumping in flow injection systems are multisyringe flow injection analysis systems (MSFIA), where a single-syringe pump was replaced by a multi-syringe pump, fabricated by adapting a typical mechanized burette of automatic titrators in order to enable a simultaneous movement of four syringes 166,167 (see schematic diagram in Fig. 1E).…”
Section: Measuring Methodologiesmentioning
confidence: 99%
“…variate calibrations, 164 or fluorimetric determination exploiting a gas-diffusion separation and quantum dot nanocrystals for detection. 165 Another smart and widely recognized approach to enhancing the solutions pumping in flow injection systems are multisyringe flow injection analysis systems (MSFIA), where a single-syringe pump was replaced by a multi-syringe pump, fabricated by adapting a typical mechanized burette of automatic titrators in order to enable a simultaneous movement of four syringes 166,167 (see schematic diagram in Fig. 1E).…”
Section: Measuring Methodologiesmentioning
confidence: 99%
“…A similar device developed later on for flow synthesis systems was called a "tube-in-tube reactor" [50]. In modern analytical flow systems, sandwich-type gas diffusion units are frequently used [193]. In flow synthetic systems, hydrogen was introduced to conduct hydrogenation [47], CO 2 was introduced to carry out carboxylation [50], and CO was introduced to perform carbonylation reactions [194].…”
Section: On-line Processes Supporting Flow Analysis and Flow Synthesismentioning
confidence: 99%
“…Multiple peaks in the emission spectra of Qdots with a single light source have been reported 2 , 3 . These peaks are affected in a different way, e.g., by the coupling of core–shell 4 , chemical compounds 5 , ions 6 , 7 , air–water surface interface 8 , and surface plasmon resonance 9 . The quenching of Qdots (CdSe) by gold nanoparticles in the vicinity was examined in detail; the distance required for the quenching is estimated at 7.5 nm.…”
Section: Introductionmentioning
confidence: 99%