2021
DOI: 10.1167/tvst.10.10.17
|View full text |Cite
|
Sign up to set email alerts
|

Selective Large-Area Retinal Pigment Epithelial Removal by Microsecond Laser in Preparation for Cell Therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
8
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 47 publications
1
8
0
Order By: Relevance
“…In particular, in the regular SRT application mode using pulse ramps, with a pulse duration of 8 µs, the performance (AUC: 98%) and the accuracy of 97% (sensitivity: 99%, specificity: 93%) are remarkable. This setting has already emerged in previous experiments [ 19 , 22 , 31 , 33 , 42 ] and is, therefore, currently also being evaluated clinically (ClinicalTrials.gov Identifier: NCT04968756). Therefore, in vivo RFD data on our SD-OCT M-scan based algorithm and the Spectralis Centaurus device should be available soon.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In particular, in the regular SRT application mode using pulse ramps, with a pulse duration of 8 µs, the performance (AUC: 98%) and the accuracy of 97% (sensitivity: 99%, specificity: 93%) are remarkable. This setting has already emerged in previous experiments [ 19 , 22 , 31 , 33 , 42 ] and is, therefore, currently also being evaluated clinically (ClinicalTrials.gov Identifier: NCT04968756). Therefore, in vivo RFD data on our SD-OCT M-scan based algorithm and the Spectralis Centaurus device should be available soon.…”
Section: Discussionmentioning
confidence: 99%
“…Sets of laser pulses with increasing energy grouped in durations of 8, 12, 16, and 20 µs were applied. The pulse energy was adapted according to a recent in vivo animal study [ 22 , 42 ] to meet the microsecond pulse duration range described in detail in the introduction. As depicted in Figure 1 c, the pulse duration was increased from top to bottom and the pulse energy was increased from left (20 µJ) to right (160 µJ).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Recently, the Spectralis Centaurus device was used at a pulse duration of 8 µs in an in vivo rabbit model to remove the RPE over a large area, allowing for a simplified subretinal injection [ 86 ]. This procedure should one day benefit RPE cell therapies and remove the host RPE cells prior to the injection of new stem cell–derived RPE cells.…”
Section: Discussionmentioning
confidence: 99%
“…In addition, TxCell technology allows for the making of confluent lesions in the treated area. Laser power was adjusted to reach the minimum visible threshold to compensate for the natural changes in the pigmentation of the pig eyes ( 59 ). Spot size of 200 μm and 330 ms of exposure time, DC of 1% (0.1 ms on to 9.9 ms off), 1.5% (0.1 ms on to 6.6 ms off), and 2% (0.1 ms on to 4.9 ms off) were used with laser power of 1800 mw (1% DC), 1600 mw (1.5% DC), and 1100 mw (2% DC).…”
Section: Methodsmentioning
confidence: 99%