2014
DOI: 10.1016/j.radphyschem.2012.12.031
|View full text |Cite
|
Sign up to set email alerts
|

Self-attenuation factors in gamma-ray spectrometry of select sand samples from Camburi Beach, Vitória, Espírito Santo, Brazil

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
1
2

Year Published

2014
2014
2019
2019

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 2 publications
0
6
1
2
Order By: Relevance
“…At 122 keV, the correction factors were found to vary between 1.04 and 1.13 for scale samples with density of 1.4-1.8 g cm À3 . The values were lower than those reported by Barros [15] for sand samples with the same density, where the correction factors ranged between 1.24 and 1.93.…”
Section: Self-attenuation Correction Factors Of Scale Samples 569contrasting
confidence: 76%
See 1 more Smart Citation
“…At 122 keV, the correction factors were found to vary between 1.04 and 1.13 for scale samples with density of 1.4-1.8 g cm À3 . The values were lower than those reported by Barros [15] for sand samples with the same density, where the correction factors ranged between 1.24 and 1.93.…”
Section: Self-attenuation Correction Factors Of Scale Samples 569contrasting
confidence: 76%
“…This approach employs additional assumptions and approximations that will increase the measurement uncertainty. A literature survey shows that most studies estimate the attenuation coefficients in soil and sediments semi-empirically using an experimental method [8,9,[14][15][16] or theoretically using Monte Carlo computation techniques. [17][18][19][20][21] To our knowledge, no efforts have been made to determine self-attenuation coefficients in scales generated from the petroleum industry.…”
Section: Introductionmentioning
confidence: 99%
“…High resolution gamma-ray spectrometry is a simple and effective method to determine the radioactive activity of environmental soil samples (Barros and Pecequilo, 2014;Conti et al, 2013). The measuring system modelled and employed in this study was a coaxial P-type high-purity germanium detector based gamma spectrometer.…”
Section: Gamma Ray Detection Systemmentioning
confidence: 99%
“…Quando as amostras apresentam densidades maiores que a da solução padrão aquosa, faz-se necessário realizar uma correção na eficiência devido a autoatenuação de cada amostra, pelo fato da curva de eficiência ter sido feita com solução radioativa padrão aquosa (Barros e Pecequilo, 2014 Cutshall, 1983).…”
Section: Fatores De Autoatenuaçãounclassified