2020
DOI: 10.1016/j.cej.2020.124932
|View full text |Cite
|
Sign up to set email alerts
|

Self-healing flexible sensor based on metal-ligand coordination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
32
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 56 publications
(32 citation statements)
references
References 38 publications
0
32
0
Order By: Relevance
“…The SPU sample shows the absorption peak at $280 nm, which is the characteristic peak of DA. 33,65 Furthermore, the glass transition temperatures (T g ) of the obtained composites were measured by DSC tests and the curves are displayed in Fig. 4(c).…”
Section: Design Synthesis and Characteristics Of Materialsmentioning
confidence: 99%
“…The SPU sample shows the absorption peak at $280 nm, which is the characteristic peak of DA. 33,65 Furthermore, the glass transition temperatures (T g ) of the obtained composites were measured by DSC tests and the curves are displayed in Fig. 4(c).…”
Section: Design Synthesis and Characteristics Of Materialsmentioning
confidence: 99%
“…Furthermore, the healing performance in terms of the mechanical properties was increased with the increase in healing time [89]. Self-healing with metal-ligand coordination was studied in synthetic rubber by Lia et al (2020) [90]. In this research, methyl vinyl silicone rubber (MVQ) was dissolved in a tetrahydrofuran solvent and reacted with DOPA and FeCl3•6H2O.…”
Section: Figurementioning
confidence: 99%
“…Reversible non-covalent self-healing flexible materials also exhibit good self-healing properties, such as hydrogen bond, [58][59][60][61][62] electrostatic interaction, [63][64][65] metal ligands and ionic interaction. [66][67][68][69][70][71][72][73][74][75] Park et al introduced strong and weak hydrogen bonds into the carboxylated polyurethane molecular chain, and successfully prepared a self-healing stretch sensor with energy storage function as shown in Figure 2a. The device has conductivity of up to 2479 S cm −1 , an elongation at break rate of 700% and a self-healing rate of 94%.…”
Section: Reversible Non-covalent Bond (Rnb)mentioning
confidence: 99%
“…[74] Cui et al prepared a self-healing matrix by introducing metal ligand coordination bond into methyl vinyl silicone rubber, and then coated the nanostructured conductive layer (multi walled carbon nanotubes (CNTs) film and silver film) on the selfhealing elastomer substrate to assemble the strain sensor. [75]…”
Section: Reversible Non-covalent Bond (Rnb)mentioning
confidence: 99%