2017
DOI: 10.15199/48.2017.12.01
|View full text |Cite
|
Sign up to set email alerts
|

Semi-analytic calculations of overvoltages caused by direct lightning strike in buried coaxial cable

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 2 publications
0
6
0
Order By: Relevance
“…The present work is a continuation of the research presented in [22]- [24]. Papers [22]- [23] dealt with a model of a single buried cable and its validation, and [24] with simplified engineering estimation of maximum values of overvoltages caused by lightning in buried systems. In the present paper, calculations of surge waveforms are carried out using analytical formulations in the frequency domain and the IFFT transform to the time domain.…”
Section: Model Of Underground Cablementioning
confidence: 99%
See 2 more Smart Citations
“…The present work is a continuation of the research presented in [22]- [24]. Papers [22]- [23] dealt with a model of a single buried cable and its validation, and [24] with simplified engineering estimation of maximum values of overvoltages caused by lightning in buried systems. In the present paper, calculations of surge waveforms are carried out using analytical formulations in the frequency domain and the IFFT transform to the time domain.…”
Section: Model Of Underground Cablementioning
confidence: 99%
“…The present work is a continuation of the research presented in [22][23][24]. Papers [22,23] dealt with a model of a single buried cable and its validation, and [24] -with simplified engineering estimation of maximum values of overvoltages caused by lightning in buried systems.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The research has been carried out with using numerical simulations based on the electromagnetic field theory and method of moments. It concerns only some of the above mentioned factors and only partly complements the study on the effects of direct lightning strikes shown in [16]- [18].…”
Section: Exposure Of Underground Cable Intrusion Detection System To mentioning
confidence: 99%
“…At the same time, up to 75-90% of the total number of electrical damages in these cable networks is due to single-phase to ground fault (SPGF) [1][2][3], which are often the primary cause of more severe accidents, accompanied by significant economic damage. At the same time, the current of the SPGF is small, since it is caused by the cable cores capacitance relative to the earth [4][5][6]. In this regard, in accordance with the EIC (Electrical Installation Code), the existence of an SPGF is allowed within two hours, while the relay protection from SPGF can act both on the trip and on the signal [7,8].…”
Section: Protection Of a Two-cable Line From Single Phase-to-earth Famentioning
confidence: 99%