“…The surface area for various batches synthesized were repeated in the same conditions and the results indicate values within the standard error of 5%. The magnetic properties were investigated in 50 Hz alternating current (ac) fields of amplitudes up to 6.4 kOe by means of a laboratory-manufactured induction hysteresigraph [22]. The instrument provides two voltage signals reproducing the time evolution of the applied field and sample contribution to the magnetic flux (at 3 Oe/V, and 0.1 Mx/V, respectively, calibration error), which were recorded at 150 kHz sampling frequency to a PC by means of a 16 bit-resolution DT-9816A (DATA TRANSLATION) data acquisition card.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The surface area for various batches synthesized were repeated in the same conditions and the results indicate values within the standard error of 5%. The magnetic properties were investigated in 50 Hz alternating current (ac) fields of amplitudes up to 6.4 kOe by means of a laboratory-manufactured induction hysteresigraph [22]. The instrument provides two voltage signals reproducing the time evolution of the applied field and sample contribution to the magnetic flux (at 3 Oe/V, and 0.1 Mx/V, respectively, calibration error), which were recorded at 150 kHz sampling frequency to a PC by means of a 16 bit-resolution DT-9816A (DATA TRANSLATION) data acquisition card.…”
Section: Methodsmentioning
confidence: 99%
“…The saturation magnetization (technical) was estimated from extrapolating to 50 kOe the data resulted from fitting the hysteresis loop branches to a superposition of Langevin-type transition functions. [22]. The saturation magnetization was estimated from extrapolating to 50kOe the fitted data.…”
Section: Methodsmentioning
confidence: 99%
“…For the analysis of magnetic properties, 276 g of F is introduced in the measuring cell of a magnetometer and the measurements are performed under sine waveform driving field conditions by means of a laboratory-made ac induction hysteresis graph that is described in Ref. [ 37 ]. The saturation specific magnetization is found to be 22.7 Am /kg, and is obtained at 477 kA/m, the remanent specific magnetization is 2.86 Am /kg, and the intensity of coercive magnetic field is 12.33 kA/m [ 33 ].…”
Section: Structural and Magnetic Characterizationmentioning
confidence: 99%
“…The magnetisation curves of MAFs are shown in Figure 1 , and were performed also under sine waveform driving field conditions by means of a laboratory-made ac induction hysteresis graph described in Reference [ 29 ]. The saturation specific magnetization occurs at about 477 kA/m, and together with the remanent specific magnetization, they generally increase with the volume fraction of mFe.…”
Section: Resultsmentioning
confidence: 99%